Acyclovir Cream, Tablet and Injection Formulations — What Each Dosage Form Demands of the API

Home / Products / Dosage Forms

Acyclovir at a Glance
CAS Number59277-89-3
Molecular FormulaC8H11N5O3
Molecular Weight225.21
PharmacopoeiaUSP / EP / BP
Packaging25 KG / drum
Solid Form3:2 hydrate (commercial form)
GMPYes (WC)
CEPCEP 2001-283-Rev 06

Acyclovir (CAS 59277-89-3) reaches the finished product through three dosage-form categories: oral solids, topical semi-solids such as acyclovir cream and ointment, and injections, which use the sodium salt. Each category places a different requirement on the API, and the specification should reflect the route the buyer's dossier describes. This page covers what each form demands, what the physicochemical profile implies for formulation, and how packaging follows from the product form.

The Three Formulated Categories

Acyclovir is an active substance, not a finished product. The categories below describe what is done with the material, not what the material contains.

Dosage formTypical presentationWhat it demands of the API
Oral solidsTablets and capsulesParticle size, flow, bulk density, blend uniformity
Topical semi-solidsCream and ointmentParticle-size distribution with method, micronized grade, dispersion behaviour
InjectionLyophilised or liquid injectionSodium salt identity and the controls that follow from a sterile route

Why the Category Changes the Specification

A specification that suits a dry blend does not suit a topical dispersion, and the difference is not in the chemical parameters. Identity, assay, impurities and water hold across all three forms.

What changes is the weight placed on the physical parameters. The pharmacopoeial tests set the floor for every route; the physical parameters are what separate a specification written for the buyer's process from one inherited from whichever supplier replied first.

Oral Solids: Tablets and Capsules

For tablets and capsules, the API is a small fraction of a much larger blend. The controlling parameters are those that determine whether the API distributes evenly through the blend and whether the blend behaves consistently on the tablet press.

Particle Size and Flow

A material whose particle size varies between batches will produce a blend whose uniformity varies with it. The variation may stay inside every chemical limit and still change the weight uniformity of the finished tablet.

The physical form adds a second variable for acyclovir. The commercial material is a hydrate, and the water it carries is part of its structure. A batch that has dehydrated or partially dehydrated behaves differently in a dry blend from one that has not — another reason the solid form belongs in the specification.

What to Specify

Bulk density with a stated method, a particle-size distribution with a stated method, and the solid form. None of the three appears in a pharmacopoeial monograph by default, and all three are legitimate additions to a purchase specification for this route.

Topical Semi-Solids: Acyclovir Cream and Ointment

A cream or an ointment is a dispersion. The API is suspended in a carrier, and the product's behaviour — how it spreads, how it feels, how stable the dispersion is on storage — depends on the size of the dispersed particles.

Dispersion and the Micronized Grade

A coarse material settles and produces a gritty product; an excessively fine one can be difficult to wet and may change the rheology of the carrier. The commercial answer is a controlled particle-size grade, usually described as micronized.

A supplier offering a micronized grade should state the distribution — typically a D10, D50 and D90 — and the method used to measure it. A nominal description without a method is not a specification, because two laboratories measuring the same material by different methods will report different distributions.

What the Specification Should Carry

For acyclovir cream or ointment, the purchase specification should carry the micronized grade, the particle-size distribution with its method, and a statement of the solid form. The chemical parameters stay where the monograph puts them.

Wetting behaviour is the practical issue in a topical product. A batch that wets differently from the previous batch changes the finished product's behaviour without changing any chemical result, which is why physical consistency between batches matters more for this route than for a dry blend.

Injection: the Sodium Salt Route

Why the Salt Changes the Material

The injectable route uses acyclovir sodium, CAS 69657-51-8, with a molecular formula of C8H10N5NaO3 and a molecular weight of 247.19. It is a separate material with its own specification, not a grade of the free base.

The sodium salt is far more water-soluble than the free base, which is the reason it exists as a commercial material. A buyer sourcing for an injectable programme should establish the salt at the enquiry stage, because a quotation for the free base does not answer the question.

What the Buyer Should Establish

The specification for acyclovir sodium carries the same chemical groups as the free base — identity, assay, related substances, water — and adds the controls that follow from the salt: sodium content and the pH of a solution prepared from the material.

The sterile controls — sterility, endotoxin and particulate matter — belong to the finished-product stage, not to the API specification. A supplier that offers "sterile API" without describing the manufacturing and packaging controls is describing a claim rather than a process.

Solubility, pKa and What They Change

The Physicochemical Profile

Acyclovir is an amphoteric molecule with two pKa values, 2.27 and 9.25, and a logP of about −1.56. Its aqueous solubility is low and pH-dependent: roughly 1.3 mg/mL in water at room temperature, rising to about 2.5 mg/mL at 37 °C, and much higher in strongly acidic media — in the region of 50 mg/mL in 1 M hydrochloric acid.

PropertyValueConsequence for formulation
pKa2.27 and 9.25Solubility and dissolution change with pH
logPabout −1.56Low lipophilicity; permeation limits oral absorption
Aqueous solubilityabout 1.3 mg/mL at room temperatureSuspension or solubilised systems rather than simple solutions
Solubility in 1 M HClabout 50 mg/mLAcidic vehicles dissolve far more material

From Solubility to Formulation

The solubility profile explains the dosage-form landscape. A molecule with high aqueous solubility and low permeability sits in BCS Class III, moving toward Class IV at the higher tablet strengths. That classification is why the oral route relies on formulation work rather than on the molecule's own properties, and why particle size matters for every solid and semi-solid route.

For a topical product, the same profile means the carrier does the work. The API is dispersed rather than dissolved, and the particle size inside the dispersion is the parameter that connects the raw material to the finished product.

Packaging and Transport

The Drum

Acyclovir is supplied in 25 KG drums. The material is slightly hygroscopic and light-sensitive, so the drum should be tight and light-protective, and the packaging format should be confirmed in writing before a first order.

The packaging configuration is part of the quotation, not a detail to be settled at shipment. A quotation that does not state the packaging has left a logistics cost out of the number.

Storage

Store below 30 °C in a dry place, protected from light. Keep the material in its original container with the batch number attached, so that the certificate remains traceable to the drum.

A drum that has been opened and left exposed will take up moisture. For a hydrate, that is not only a water-content question; it is a solid-form question, and the answer shows up in the next certificate.

What the Specification Should State, by Route

RouteAdd to the pharmacopoeial specification
Tablets and capsulesParticle-size distribution with method, bulk density with method, solid form
Cream and ointmentMicronized grade, particle-size distribution with method, solid form, dispersion behaviour
InjectionAcyclovir sodium identity, sodium content, pH of solution, sterile-route controls at the finished-product stage

The table is a starting point, not a template. The route the buyer's dossier describes determines which rows apply, and the buyer's own process development determines the values.

A specification written for a topical route and carried to an oral-solid route is a specification that was never reviewed. The chemical parameters travel; the physical ones do not.

From Pilot Batch to Commercial Supply

A pilot batch is often made from a small-scale process, and the specification that suited it may not suit commercial supply. The physical parameters are where the difference usually appears: particle size and bulk density can shift when the process moves to a larger reactor and a different drying configuration.

A buyer should therefore write the specification for the commercial process, not for the pilot material. The pilot batch is the evidence that the specification can be met; it is not the specification.

Where the two differ, the difference should be documented before the scale-up order, not discovered at the first commercial delivery.

Working With a Supplier on a Dosage-Form Programme

An API supplier does not formulate, and a buyer should not expect formulation support. What the supplier can do is supply material whose physical parameters are consistent and describe it accurately.

The brief should name the dosage form, the process, the particle-size distribution required with its method, the packaging configuration and the documentation scope. A brief restricted to the first item gets a quotation for an API; a brief covering all five gets a quotation for a raw material matched to a process.

The question that reveals most is how the material has behaved in the buyer's type of process before. A supplier answering from experience describes material; a supplier answering from a catalogue entry describes a product name.

Frequently Asked Questions

Oral solids such as tablets and capsules, topical semi-solids such as acyclovir cream and ointment, and injections. The injectable route uses the sodium salt rather than the free base.

No. Identity, assay, impurities and water hold across all three forms. What changes is the weight placed on physical parameters — particle size, bulk density and solid form — which rise from optional to required for a topical or oral-solid route.

Because the cream is a dispersion. Particle size controls how evenly the API disperses in the carrier, and an inconsistent distribution between batches changes the finished product's behaviour without changing any chemical result.

Acyclovir sodium is the sodium salt, CAS 69657-51-8, molecular formula C8H10N5NaO3 and molecular weight 247.19. It is used for the injectable route and specified separately from the free base.

Because it has low permeability and, at the relevant doses, high aqueous solubility. The classification moves toward Class IV at the higher tablet strengths, which is why formulation work carries so much of the oral route.

25 KG per drum, in a tight, light-protective container. Store below 30 °C in a dry place, and keep the batch number with the container so the certificate stays traceable.

Sources

  • Acyclovir fine-powder and micronized specification sheets — grades and particle-size parameters
  • FDA product labelling — aqueous solubility at 37 °C
  • Published physicochemical summaries — pKa values, logP and BCS classification
  • Manufacturer specification data — salt form, packaging and storage as supplied
Request a Acyclovir API specification and quotation

Send the standard you are quoting against, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.

INFO@KINGWISH.CN