| CAS Number | 59277-89-3 |
|---|---|
| Molecular Formula | C8H11N5O3 |
| Molecular Weight | 225.21 |
| Pharmacopoeia | USP / EP / BP |
| Packaging | 25 KG / drum |
| Solid Form | 3:2 hydrate (commercial form) |
| GMP | Yes (WC) |
| CEP | CEP 2001-283-Rev 06 |
Sourcing acyclovir API from China is a documentation exercise before it is a commercial one. The material is mature, the pharmacopoeial standards are public, and the supplier base is broad — which means the differences between offers sit in the filing, the site and the specification rather than in the molecule. This guide sets out how to separate a manufacturer from a trader, what the registration documents actually cover, and the checks to run before a purchase order.
China is one of the main production bases for acyclovir API. Public supply directories list Chinese manufacturers alongside those in India, Italy and Spain, and the Chinese sites are frequently the ones behind the quotations that reach European and North American formulators.
Acyclovir is an old molecule with a well-documented chemistry. That matters for sourcing: the barriers to entry are regulatory rather than technical, and the supplier landscape reflects it. Many companies can make the material; fewer hold the filings that let a buyer use it.
The origin of a batch tells a buyer where the material was manufactured. It does not tell the buyer who manufactured it, which is the question that matters.
A Chinese trading company can offer acyclovir from a site it does not own, and a site can sell through several trading companies at once. Neither arrangement is improper, but only one of them gives the buyer a route to the batch record and the site's quality function.
Three questions separate the layers, and none of them requires proprietary information.
A manufacturer answers all three directly. A trading arm answers for its own site and forwards the rest. A trader forwards all three, and the quality of the answer depends on its relationship with the site.
Trading arms are normal in the Chinese industry. A manufacturing group may sell through a dedicated trading subsidiary, and a buyer may deal with a trading arm that has direct access to the site's documents.
The distinction that matters is not legal form but document access. A trading arm that can produce the site's GMP certificate, the specification revision and the batch record is functionally equivalent to the site for evaluation purposes. A trader that cannot is a middleman, and the buyer should price the additional uncertainty accordingly.
For the United States, the API is referenced through a Drug Master File submitted to the FDA. The DMF describes the manufacture, the controls and the facilities, and it is reviewed when a finished-product application references it.
A DMF is a filing, not an approval. A supplier that holds one has submitted the document; whether it supports a given product depends on the application that references it.
For Europe, the route is usually the Certificate of Suitability issued by the EDQM, or an ASMF referenced in a marketing authorisation application.
The CEP states that the material complies with the Ph. Eur. monograph. It is site-specific: the certificate names the manufacturer and the manufacturing site, and a change of site requires a new or revised certificate.
Separately, APIs imported into the EU from third countries are subject to the written-confirmation requirement for the manufacturer's GMP status. The written confirmation and the CEP are different documents serving different purposes, and a buyer should establish which of them the supplier holds.
The supplying site behind this page holds CEP 2001-283-Rev 06, and US FDA establishment identifier FEI 3002808516 is on record for the site. A buyer should confirm the current revision of the CEP and that the certificate names the site that will manufacture the batch.
| Question | DMF (US) | CEP (EU) |
|---|---|---|
| Who issues it | The manufacturer submits; FDA reviews on reference | EDQM issues after assessment |
| What it covers | The manufacture, controls and facilities described in the file | Compliance with the Ph. Eur. monograph |
| Is it site-specific | Yes, through the facilities described | Yes, the certificate names the site |
| Does it authorise a product | No | No |
The public picture is broad. Supply databases record several dozen manufacturers with active filings, of which a substantial minority hold either a US DMF or a CEP — and holding one does not imply holding the other. Public CEP records for acyclovir include certificates such as R1-CEP 2003-041-Rev 05 and R1-CEP 2007-213-Rev 01, alongside the site-specific certificate held for this supply route.
The document set for acyclovir is the standard API set for a pharmacopoeial material:
The documents are meant to be read together. The specification names the limits; the methods determine whether those limits can be reproduced; the certificate shows what a real batch looked like against them.
A buyer who reads only the certificate is reading a result without the rule it was judged against. A buyer who reads only the specification is reading a rule without evidence that it was applied.
An audit of a mature API site is not a search for defects. It is a confirmation that the site's systems match the documents the buyer has been given.
The checklist that carries the most weight for acyclovir:
The documents describe what the site says it does. The audit confirms whether the described systems are in place. For a mature product the gap is usually small — but the buyer's due diligence obligation does not shrink because the product is old.
An assay figure without "dried basis" is a number without a convention. For a hydrated material, the difference between dried-basis and as-is results is large enough to make two identical batches look different.
A specimen certificate without a batch number is a template. Templates are acceptable at enquiry stage if labelled as such; they are not acceptable as evidence of release.
"CEP available" is not a statement that the CEP covers the site that will make the batch. The certificate number and the named site belong in the quotation.
A specification that changes between the enquiry and the order is a specification that was never agreed. The revision number should be quoted with the offer and repeated on the order.
A complete quotation for acyclovir answers more than the price. It names the material by CAS number and monograph, states the specification revision, identifies the manufacturing site and its GMP certificate, states the filing that covers the site, specifies the packaging and states the documentation that will accompany the batch.
A quotation missing any of those items has left a question open, and the question will be answered later — at goods-in, at the filing review or at the audit. The cost of answering it later is always higher than the cost of asking now.
Buyers comparing offers should normalise them against the same list before comparing numbers. Two quotations that differ in specification revision or packaging are not quotes for the same thing. For a buyer sourcing acyclovir API from China for the first time, this list is also the fastest way to see which suppliers are describing a site and which are describing a catalogue.
The first order establishes the relationship; repeat orders test whether the process is stable. The documents that matter for a repeat order are the same ones, read against the same specification revision.
A supplier that changes the specification revision between orders should explain why. A revision is not automatically a problem — processes improve — but an unexplained revision is a change whose effect on the buyer's process has not been assessed.
Buyers should keep the specification revision and the certificate of each batch. The sequence is the evidence base for the next supplier review, and it is the only way to see a trend before it becomes a deviation.
Send the standard you are quoting against, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.