| CAS Number | 59277-89-3 |
|---|---|
| Molecular Formula | C8H11N5O3 |
| Molecular Weight | 225.21 |
| Pharmacopoeia | USP / EP / BP |
| Packaging | 25 KG / drum |
| Solid Form | 3:2 hydrate (commercial form) |
| GMP | Yes (WC) |
| CEP | CEP 2001-283-Rev 06 |
Acyclovir quality standards rest on a pharmacopoeial monograph, and three of them are in current commercial use: the United States Pharmacopeia, the European Pharmacopoeia and the British Pharmacopoeia. This guide compares what the three documents cover, explains the lettered impurity system, and sets out how to read an acyclovir certificate of analysis against the standard the batch was released against.
The three pharmacopoeias describe the same substance under the same CAS number. They differ in title, in editorial convention and occasionally in the wording of a test — not in the identity of the material.
A buyer therefore does not choose a "different acyclovir" by choosing a monograph. A buyer chooses which document's limits and methods the batch will be judged against, and that choice follows the destination market's registration.
The USP monograph is titled Acyclovir. The Ph. Eur. and British Pharmacopoeia monographs are titled Aciclovir. Both names resolve to CAS 59277-89-3.
The practical consequence appears on paperwork. A specification that quotes "Aciclovir, Ph. Eur." and a certificate that says "Acyclovir" describe the same material, but a reviewer encountering the pair without the CAS number has to stop and reconcile them. Stating the CAS number on both documents removes the question.
All three monographs address the same groups of tests:
| Group | What it establishes |
|---|---|
| Identification | That the material is acyclovir, by infrared and ultraviolet absorption against reference spectra |
| Assay | The content of acyclovir by liquid chromatography, calculated on the dried basis |
| Related substances | The lettered impurity system, with individual limits and a total |
| Water | The water content, by Karl Fischer titration |
| Physical tests | Appearance and the monograph's remaining tests |
The limits themselves belong to the current edition of each monograph. This page does not restate them, because a limit quoted from memory is worse than a limit quoted from the document: pharmacopoeial texts are revised, and the revision the batch was released against is the only one that matters.
Acyclovir's related substances are specified through a lettered system. Individual reference standards are commercially available for the letters, which is what allows a laboratory to identify and quantify each specified impurity rather than report a single combined figure.
Reference-standard catalogues for the current Ph. Eur. edition list impurities including:
| Impurity | Identity note | CAS |
|---|---|---|
| B | Guanine | 73-40-5 |
| C | — | 91702-61-3 |
| J | C14H16N10O4, MW 388.34 | 166762-90-9 |
| K | N-methylene dimer, C17H22N10O6, MW 462.42 | 1797131-64-6 |
| M | C12H15N5O5, MW 309.28 | 91702-60-2 |
| P | C7H9N5O2, MW 195.18 | 23169-33-7 |
| Q | Dimer of the acyclovir unit (2 × C9H13N5O4) | — |
| R | C17H22N10O6, MW 462.42 | — |
These are catalogue identities, not acceptance limits. The limits, the reporting threshold and the disregard limit are set by the monograph, and the specification document issued by the manufacturer should reproduce them with its own revision number.
Guanine is the impurity that receives the most attention, for a reason that follows from the chemistry: it is the starting material of every commercial route and a hydrolysis product of the finished molecule.
That dual origin means a guanine result carries two pieces of information at once. A level that rises because the synthesis did not run to completion is a process problem; a level that rises on storage is a degradation problem. The same number, read on a single certificate, cannot distinguish them. A sequence of certificates can.
Ask for the related-substances section of the certificate with the individual results, not a summary line. A supplier able to produce the full profile is a supplier whose analytical system is running; a supplier that can only produce a total has produced a number without a rule.
Read the individual results against each other. A batch with a clean total but one impurity near its limit is a batch where a specific step is drifting, even though the aggregate still passes. Buyers who track individual results across batches see that drift before it becomes a rejection.
Acyclovir assay is determined by liquid chromatography and expressed on the dried basis. The basis is the part that decides whether two figures can be compared.
Water is excluded from a dried-basis calculation and included in an as-is calculation. For a hydrated material, the difference is not academic: the commercial form carries water as part of its structure, and the same lot reports two different figures depending on the convention.
Water content is a monograph test in its own right, and for acyclovir it does double duty. It is a specification parameter, and it is also the signal of which solid form the batch contains.
A water result that is consistent with the 3:2 hydrate and a water result that merely falls inside the limit are different statements. The first tells the buyer what the material is; the second tells the buyer that a number passed a threshold. The specification should ask for the first.
Residual solvents are controlled under ICH Q3C, and the certificate should name the solvents the route can carry and report each result. The solvents that matter follow from the synthesis: the route determines the list.
A buyer comparing two suppliers should compare the actual results, not only whether both pass. A result near a limit and a result an order of magnitude below it describe two different drying and purification regimes.
Elemental impurities are handled through a risk assessment under ICH Q3D rather than through a single heavy-metals number. The assessment identifies the elements the process can introduce and sets control thresholds accordingly; the certificate reports results against that assessment.
A certificate that states "heavy metals ≤ 10 ppm" without more is reporting a legacy test, not a Q3D risk assessment. Buyers in regulated markets should ask which document applies.
The physical tests — appearance, water, and the monograph's remaining checks — are cheap to run and easy to overlook. They are also the group that most often explains a downstream problem, because a material can pass every chemical test and still behave differently in a process if its physical form has moved.
A certificate is read against the specification it cites. It is not read in isolation, because a result that passes a limit not in the specification has passed nothing.
The reading order is fixed: identity of the batch, correspondence of the test items to the specification, methods cited, limits, results, release authorisation.
Product name, CAS number, batch number, manufacturing date, re-test or expiry date, the specification reference and its revision, and the solid form where the specification names one.
The batch number must be populated. A specimen without one is a template.
One row per test item, with the method, the limit and the result. The comparison is three-way: does the item appear in the specification, does the method match the methods document, and does the result fall inside the stated limit.
A result reported without its limit is not a release decision. A result reported against a limit the specification does not contain is a revision mismatch, and it should be resolved before acceptance.
The statement identifies who authorised the release and when. It should trace to the manufacturing site's quality function even where the certificate is issued by a trading arm.
Read the identity block first and confirm the CAS number and molecular weight against the material being bought. Then read the assay line and confirm its basis. Then read the impurity section and confirm that individual results — not only a total — will appear on the certificate. Then read the residual solvent, elemental impurity and physical sections. Finally, confirm the revision number and the monograph the specification is written against.
A specification that can be summarised accurately on one page — identity, monograph, assay basis, impurity limits, solvents, water, physical parameters, revision — is a specification that can be worked with. One that cannot be summarised has not been read carefully enough.
A pharmacopoeial monograph sets the floor. The manufacturer's specification records the operating detail. The certificate is the evidence that both were met. The three documents only work together, and a buyer who reads one without the other two is reading a fragment.
At enquiry stage, ask for the specification document by revision, the certificate of analysis for a representative batch and the table of contents of the analytical methods package.
Those three documents answer the questions a buyer needs before a quotation can be evaluated: what the limits are, what a real batch looked like against them, and whether the methods behind the results can be reproduced.
The remaining documents — validation reports, stability data, the elemental-impurity assessment — can follow at the audit stage. Requesting them all at once slows the enquiry without changing the decision. Those three documents are the acyclovir quality standards as they apply to a specific batch.
Send the standard you are quoting against, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.