| CAS Number | 59277-89-3 |
|---|---|
| Molecular Formula | C8H11N5O3 |
| Molecular Weight | 225.21 |
| Pharmacopoeia | USP / EP / BP |
| Packaging | 25 KG / drum |
| Solid Form | 3:2 hydrate (commercial form) |
| GMP | Yes (WC) |
| CEP | CEP 2001-283-Rev 06 |
Acyclovir (CAS 59277-89-3) is polymorphic and pseudopolymorphic: the same molecule can crystallise as anhydrous forms and as hydrates, and the solid form it takes changes its physical behaviour without changing its chemical identity. This page sets out the forms reported in the literature, the hydrate that is supplied commercially, the transitions between forms, and what a buyer should specify. The acyclovir polymorphs and hydrates described below are the ones a buyer is most likely to encounter in a specification review.
The literature on acyclovir describes several anhydrous forms, a dihydrate and the hydrate used commercially. The forms differ in crystal packing, in water content and in the way the material behaves when heated, wetted or stored.
For a buyer, the point is not to memorise the forms. The point is that a certificate can report the same assay, the same impurities and the same water content for two batches that behave differently in a process, because the physical arrangement of the molecules differs.
Three properties move with the form, and each has a downstream consequence:
| Property | What changes | Consequence |
|---|---|---|
| Water content | The hydrate carries water as part of its structure | Drying, blending and storage behaviour |
| Crystal packing | Different habit and surface properties | Flow, wetting and dispersion |
| Thermal behaviour | Different dehydration and melting paths | Drying limits and process temperatures |
None of these appears on a standard assay line. All three are visible in a specification that asks for them.
The material supplied as API is normally the 3:2 acyclovir-to-water hydrate, often called the 2/3 hydrate. The form is monoclinic, space group P21/n, with unit-cell parameters of approximately a = 25.459 Å, b = 11.282 Å, c = 10.768 Å and β = 95.16°.
The structure contains three acyclovir molecules stacked in a parallel arrangement, with two water molecules occupying a channel through the packing. That architecture is what makes the water part of the solid rather than an adsorbed impurity.
The commercial hydrate is the form the manufacturing processes have been designed around. It is stable under ordinary storage conditions, it handles well in the operations that follow crystallisation, and its water content is reproducible when the drying step is controlled.
A buyer does not need to know the crystallography. A buyer needs a certificate that identifies the form, and a supplier that can explain what happens to it under the buyer's storage and processing conditions.
Anhydrate I is obtained by heating the commercial material to about 180 °C. It is orthorhombic, packs in a parallel arrangement, and was reported as an air-stable needle form in the study that characterised the series.
For a buyer, anhydrate I matters mainly as a transition state. Material that has been over-dried can move toward it, and the change is not reversed simply by returning the drum to ambient conditions.
Anhydrate II is obtained by rapid evaporation from methanol and is monoclinic. It packs in an antiparallel arrangement, distinct from both the hydrate and anhydrate I.
The form appears in the transition map at low humidity: the commercial hydrate converts toward anhydrate II at near-zero relative humidity.
Two further anhydrous forms were reported under non-ambient conditions: a metastable form obtained by heating the commercial hydrate to about 130–150 °C, and a high-temperature form obtained by heating anhydrate I above about 180 °C.
These forms are of interest to a process scientist rather than to a purchaser. They matter because they show how many ways the solid can rearrange when a drying or milling step is pushed beyond its design space.
A 1:2 acyclovir-to-water dihydrate — two water molecules per acyclovir molecule — has been reported, obtained through polymer-induced crystallisation. It is triclinic and packs in a parallel arrangement.
The dihydrate and the commercial 3:2 hydrate have similar internal packing but different water content and different spectroscopic signatures. The dihydrate converts to the 3:2 hydrate below about 20% relative humidity, which places it outside the ordinary storage window of the commercial material.
Dehydration of the dihydrate produces a metastable form that the literature numbers separately. It is a reminder that the hydrate system is not a pair of states but a landscape, and that a process change can move material into a part of it that the specification never contemplated.
The transitions that matter for storage are humidity-driven:
Ordinary warehouse conditions sit well inside these extremes, which is why the commercial hydrate is stable in normal storage. A drum left in a humid environment or a dry room is a different situation.
The 3:2 hydrate converts to a further anhydrous form above about 120 °C, and anhydrate II converts to another form above about 170 °C.
Those temperatures are well above ordinary storage conditions but well within the range a drying operation can reach. A drying step that is not controlled for the solid form can dehydrate the surface of a batch while the certificate continues to report a water content inside its limit.
The commercial hydrate dehydrates to anhydrous form I in methanol, ethanol or DMF. Form I converts to form II in dry methanol or DMF, and added water inhibits the conversion. DMSO produces a gel composed of crystalline form II.
For a buyer, the solvent transitions matter in two places: in the supplier's crystallisation and drying operations, and wherever the buyer wets the material during formulation.
The purchase specification should state the solid form, the water content with its method, and — for routes where particle size matters — the particle-size distribution with its method.
A specification that states only "white to off-white crystalline powder" leaves the form open. The phrase describes every form in this article.
The tests that identify the form depend on the laboratory, and the literature uses several: X-ray powder diffraction, Raman spectroscopy, terahertz spectroscopy, solid-state NMR, differential scanning calorimetry and vapour-sorption analysis.
For routine batch control, X-ray powder diffraction and water content are the practical pair: the first identifies the form, the second confirms that the water is where the form puts it. For a problem investigation, differential scanning calorimetry and dynamic vapour sorption show how the batch behaves when it is heated or exposed to humidity.
A buyer placing a first order should ask which of these tests the supplier runs, and what the results look like across consecutive batches. The question is not whether one batch was the right form; it is whether the process produces the right form every time.
The solid form changes the material's surface and its packing, and both properties matter downstream. A form with a different habit wets differently, flows differently and disperses differently.
For an oral solid, those differences show up in blend uniformity and in the tablet's dissolution behaviour. For a topical semi-solid, they show up in how evenly the API disperses in the carrier. In both cases the chemical certificate can be unchanged while the process outcome moves.
That is why the specification for a solid or semi-solid route should carry the form and the particle-size distribution, and why a supplier's batch-to-batch consistency in those parameters is worth as much as its impurity performance.
The literature does not use a single numbering scheme for acyclovir's forms. The 3:2 hydrate appears under several names, the dihydrate under others, and different papers number the anhydrates differently.
A buyer reading two documents that disagree should compare composition and structure rather than form number. "Form V" in one paper and "the 2/3 hydrate" in another may describe the same solid; "form I" in two papers may not.
The specification avoids the problem by describing the material: the hydrate composition, the water content and — where relevant — the X-ray powder diffraction pattern.
A form change does not announce itself on a certificate. The assay, the impurities and the appearance can all remain inside their limits while the solid form has moved.
The signals are indirect. Water content that has drifted toward one end of its range, a melting trace that shows a different dehydration pattern, or a particle-size distribution that no longer matches the previous batch are all consistent with a form change.
Confirmation requires a form-specific method: X-ray powder diffraction is the standard. A buyer who suspects a change should ask for the diffraction pattern of the batch alongside the pattern of the reference batch, and compare them rather than compare the form numbers in the two certificates.
A solid-state specification for acyclovir carries three items: the solid form, the water content and, where the route requires it, the particle-size distribution. Each should have a method.
The form can be identified by X-ray powder diffraction against a reference pattern. Water content is measured by Karl Fischer. Particle size is measured by laser diffraction with a stated dispersion method.
The specification should also state what happens when a result is outside its limit: whether the batch is rejected or investigated. For a hydrate, an out-of-limit water result is a form question as much as a chemical one, and the investigation should treat it that way. Written this way, the specification records what the acyclovir polymorphs and hydrates literature establishes, rather than assuming that any crystalline powder is the same material.
Send the standard you are quoting against, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.