| CAS Number | 59277-89-3 |
|---|---|
| Molecular Formula | C8H11N5O3 |
| Molecular Weight | 225.21 |
| Pharmacopoeia | USP / EP / BP |
| Packaging | 25 KG / drum |
| Solid Form | 3:2 hydrate (commercial form) |
| GMP | Yes (WC) |
| CEP | CEP 2001-283-Rev 06 |
Acyclovir (CAS 59277-89-3) is a stable molecule under ordinary conditions, but its stability is conditional: it is pH-dependent in solution, sensitive to light, and sensitive to moisture in the solid state because the commercial material is a hydrate. The acyclovir stability profile is conditional rather than absolute, and it is best read as a set of boundaries. This page sets out what the published stability work establishes, what it means for storage and packaging, and what a buyer should ask for.
Stability data for an API is generated under the ICH conditions: long-term, intermediate and accelerated storage, with the tests chosen to detect the degradation pathways the molecule can take.
For acyclovir the relevant pathways are hydrolysis, oxidation, photolysis and thermal degradation. A stability programme that tests only assay and appearance addresses one of the four. An acyclovir stability summary should therefore name the pathways it tested and show the results for each.
A buyer evaluating a supplier should ask for the stability summary rather than a single time point: which conditions, which time points, which tests, and which degradation products appeared.
The summary is more informative than a shelf-life number, because it shows the direction the material moves. A material whose assay drifts downward while impurities rise is telling a different story from one whose results are flat.
Acyclovir in aqueous solution is stable over a broad middle range — roughly pH 4 to 8 — with hydrolysis proceeding very slowly at pH 5 to 7, where the half-life is measured in months.
Outside that window the rate increases. Strongly acidic and strongly alkaline conditions both promote hydrolysis of the N-9 side chain, and the product is guanine.
Guanine, impurity B, CAS 73-40-5, is the hydrolysis product. That single fact connects the stability programme to the impurity profile: a guanine result on a certificate is partly a process signal and partly a history signal.
For a finished-product formulator, the implication is that aqueous formulations need their pH inside the stable window and their processing time controlled. For an API buyer, the implication is that a batch's guanine level should be read alongside its age and storage history.
The pH range also explains why acyclovir is formulated as it is. Solutions that hold the molecule at a pH where it is stable, and suspensions that keep it out of solution altogether, are both ways of avoiding the hydrolysis pathway.
A buyer sourcing API for a liquid or semi-solid route should confirm that the intended formulation pH sits inside the stable window. That is a formulation question, but it changes what the buyer needs from the API's stability data.
Oxidation is the second degradation route. It appears in forced-degradation studies under peroxide and oxygen stress, and it produces a set of degradants distinct from the hydrolysis products.
The oxidative pathway matters because it is the one most easily triggered by handling. Residual peroxides in a solvent, air in a poorly sealed container or an incompatible excipient can all move the material along it.
Control is partly a packaging question — a tight container limits oxygen exposure — and partly a process question, because the solvents and the drying regime determine what the material carries into the drum.
For a stability summary, the useful data is the oxidative degradant trend under accelerated conditions. A flat trend across the accelerated time points is the evidence that the packaging and the process are holding.
Acyclovir is sensitive to ultraviolet light. Exposure at 254 nm produces photodegradation, and the ICH photostability protocol — ultraviolet and visible light under controlled conditions — is part of a complete stability programme.
The practical consequence is that the material is supplied in a light-protective container and should be stored away from direct light.
A light-protective container is not a marketing preference. For a material that degrades under ultraviolet exposure, the container is part of the control strategy, and a change of container is a change that should be supported by stability data.
Buyers should treat a supplier's packaging as part of its specification: the drum, the liner and the light protection are all doing work.
The commercial material is the 3:2 acyclovir-to-water hydrate. Its stability in the solid state is therefore tied to moisture: the hydrate is the stable form in ordinary conditions, and the transitions to and from it are driven by relative humidity.
The literature describes the transitions: anhydrate I converts to the 3:2 hydrate above about 95% relative humidity, the hydrate converts toward anhydrate II at near-zero humidity, and the dihydrate converts to the 3:2 hydrate below about 20% relative humidity.
Ordinary warehouse conditions sit inside those extremes. A drum stored in a humid room, or a batch left open during dispensing, does not.
The 3:2 hydrate converts to a further anhydrous form above about 120 °C. That temperature is far above storage conditions but within the range a drying operation can reach, which is why drying is a controlled step rather than a simple moisture removal.
For a buyer, the storage condition follows from the same physics: below 30 °C, dry, protected from light. The condition is not a formality; it keeps the material inside the region where the supplied form is stable.
Store below 30 °C in a dry place, protected from light, in a tight container. The material is slightly hygroscopic, so the container is the first line of control.
Records should link the drum to the certificate: the batch number stays with the container, and the container stays closed when it is not in use.
Acyclovir is supplied in 25 KG drums. The drum should be tight and light-protective, and the liner should be compatible with the material.
A buyer changing the packaging — for example, repacking into smaller containers for a pilot batch — takes on the stability question that the original packaging was answering. That is a legitimate operation, but it should be supported by the buyer's own data.
Acyclovir is a powder, and the handling controls follow from that: dust control at weighing and dispensing, appropriate personal protective equipment, and cleaning procedures that prevent cross-contamination with other materials in the same area.
The safety data sheet is the reference for the specific controls the manufacturer recommends. It should be read alongside the specification, not instead of it: the specification describes what the material is, the SDS describes how to handle it.
Accelerated stability data compresses months of ambient storage into weeks at elevated temperature and humidity. For acyclovir, the value of the accelerated condition is that it drives the two pathways that matter most: hydrolysis and moisture-mediated form change.
A useful accelerated summary reports assay, water content, the individual impurity results and appearance at each time point, not only the first and last. The shape of the curve distinguishes a material that is holding from one that is drifting.
Buyers should read the accelerated data alongside the long-term data. Long-term data describes what happened; accelerated data describes what the material is capable of doing. A material that moves under accelerated conditions but is flat in long-term storage is telling the buyer where its margin lies.
The packaging of a hygroscopic, light-sensitive material is part of its control strategy. A supplier that changes the drum, the liner or the light protection is changing a variable that the stability programme was covering.
For a buyer, the question to ask is whether the new packaging is supported by data or by judgement. A supplier that can show the comparison is describing a controlled change; one that cannot is describing a decision.
The same logic applies to the buyer's own repacking. Moving material into smaller containers for a pilot batch is a legitimate operation, but the smaller container takes on the moisture and light protection the original drum provided, and the buyer's own stability data should support it.
A batch certificate reports the material at the moment of release. It says nothing about how the batch will behave after a year in the buyer's warehouse, and it says nothing about the stability of a formulation made from it.
Those questions belong to the stability summary and to the buyer's own studies. The certificate's water content and impurity results are a starting point: they describe the state the stability clock started from.
A buyer should therefore read the certificate and the stability summary together. A batch released with a water content at one end of the specification range is a different starting point from one released at the other end, particularly for a hydrate.
A storage and handling protocol turns the stability data into instructions the warehouse and the plant can follow. For acyclovir it has four elements: the temperature limit, the humidity control, the light protection and the container discipline.
The protocol should also define what happens when a container is opened. A drum that is opened for dispensing and left open has moved outside the conditions the stability data describe, and the protocol should say how long an open container may remain in use and how it is resealed.
Those instructions belong with the material, not only in the quality manual, because the people who handle the drum are the people who keep the material inside its stable region. They are the practical form of the acyclovir stability data, and they should be reviewed whenever the data are updated.
Send the standard you are quoting against, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.