0086 532 85065286 INFO@KINGWISH.CN Qingdao, Shandong, China

Erythromycin Thiocyanate Supplier Audit Checklist

Home / Products / Supplier Audit Checklist

Erythromycin Thiocyanate at a Glance
Common nameErythromycin thiocyanate
CAS number7704-67-8
Molecular formulaC37H67NO13·HCNS (equivalent to C38H68N2O13S)
Molecular weight793.02
Related formErythromycin base, CAS 114-07-8, molecular weight 733.94
Pharmacopoeial statusIn-house specification — no pharmacopoeia monograph
Anhydrous bioassay≥755 u/mg, per in-house specification
Packaging20 KG / drum
GMP statusSupplier-stated; certificate to be verified
FDA registration numberNone
CEP numberNone
Audit domainsQuality system · Analytical capability · Documentation controls · Supply chain transparency
Check items50, grouped A to D

Erythromycin thiocyanate (CAS 7704-67-8) is a macrolide antibiotic supplied as a pharmaceutical intermediate and veterinary-grade API, with the molecular formula C37H67NO13·HCNS and a molecular weight of 793.02. This page is a working audit instrument for buyers qualifying a supplier of that material: four audit domains, the evidence that closes each item, and a 50-item tick-box checklist. An erythromycin thiocyanate audit runs before a first order is placed, and its findings either support or block the qualification decision.

At a Glance

How to Use This Checklist

This checklist is used at the supplier qualification stage, before a first order is placed, and it covers four domains: quality system, analytical capability, documentation controls and supply chain transparency. It is written for erythromycin thiocyanate specifically, so the salt form and the assay basis are items to be checked rather than assumptions. An item is closed when the supporting document has been reviewed, not when the question has been answered.

When the checklist is used in the qualification sequence

The checklist is applied after the specification and the document list have been agreed and after a sample has been evaluated, and before a first commercial order is placed. In the sourcing sequence it occupies the supplier audit stage, between documentation review and first order. Order matters: the assay basis is agreed when the specification is written, and the audit then checks that the certificate of analysis reports the result on that basis.

How to record a verdict

Each item is recorded as met, partially met or not met, and stays open until the document that supports it has been received and reviewed. A verbal assurance does not close an item, nor does a document promised for later.

Evidence classExamplesWeight in the verdict
Controlled document from the supplier's quality unitSpecification, certificate of analysis, written methodCloses the item when current and complete
Record from manufacture or testingBatch record, analytical worksheet, calibration recordCloses the item when traceable to a batch or date
Third-party documentSite certificate, contract laboratory reportSupports the item; check the scope covers the activity audited
Written statement without a supporting recordEmail confirmation of a practiceLeaves the item open; record as a finding

What a completed checklist does not prove

A completed checklist does not prove lot-to-lot consistency, and it does not transfer testing responsibility from the buyer to the supplier. It records what the supplier's system provided on the audit date, for the batches sampled. Complete documentation does not prevent a delivered batch failing the buyer's incoming test, and regulatory registration is recorded rather than scored: erythromycin thiocyanate holds neither an FDA registration number nor a CEP number as supplied.

Desk review, remote audit and on-site audit

A desk review, a remote audit and an on-site audit answer different questions, and the mode should be chosen deliberately rather than by default. A desk review examines documents only, a remote audit adds live interviews and screen-shared records, and an on-site visit adds direct observation of the facility. The desk review filters what needs live verification; the on-site visit verifies what a document cannot show.

Quality System

A quality system review establishes whether the manufacturing site operates under a documented pharmaceutical quality system with a quality unit that can hold a batch or refuse a release. For erythromycin thiocyanate the review starts with the scope and currency of the site's GMP certificate, because a certificate that exists may not cover the operations that produce this material. Reviews are conducted against a framework such as ICH Q7.

GMP scope

The GMP audit question is not whether a certificate exists, but what the certificate covers. Confirm that the certificate names the site that manufactures the material, that its scope includes the steps this material passes through, and that it is current.

The manufacturer states that erythromycin thiocyanate is produced at a GMP-certified manufacturing site; the audit verifies the certificate and the site it names. Where the certificate is needed for a registration file, raise the scope at enquiry stage.

Change control

Change control determines whether the material a buyer qualifies in one year is the material supplied in the next. Ask for the written procedure, then ask which categories trigger it: starting material source, process parameters, equipment, specification limits and analytical methods. Beyond the procedure, ask for a written commitment to notify customers before a change is implemented.

Deviation handling

Deviation handling determines what happens when a batch does not follow the process. Ask for the written procedure covering recording, investigation, impact assessment and closure, and ask whether a batch can be released while a deviation remains open. A site reporting no deviations in twelve months is describing its reporting threshold, not the absence of events.

Annual review

An annual product quality review, or an equivalent periodic review, aggregates the year's batch data, deviations, out-of-specification results, complaints, changes and stability results into one document. Ask whether it is performed and whether a summary can be shared: it shows whether audit findings are isolated events or a pattern.

Analytical Capability

Analytical capability determines whether the supplier can generate the release data it reports, and whether those results will reproduce on the buyer's own bench. For erythromycin thiocyanate, two items carry particular weight: the microbiological bioassay method that produces the u/mg result, and the basis — anhydrous or as-is — on which that result is expressed.

HPLC

High-performance liquid chromatography carries identity testing, related substances and part of the assay work. Ask whether the system is on site, whether qualification records exist, and whether calibration is current. At method level, ask whether a system suitability check with stated acceptance criteria is written into each method, and who reviews the chromatograms before results are reported.

Bioassay method

The potency result for erythromycin thiocyanate is expressed in units per milligram, which is a microbiological assay result read against a reference standard. The ≥755 u/mg figure is an in-house specification for this material rather than a pharmacopoeia limit, so the method document is the only place it can be verified.

Ask for the method, the reference standard's traceability, and a sample calculation from a recent batch. Then ask whether the result is calculated on the anhydrous material or on the material as supplied: the two bases give different numbers for the same lot.

Related substances

The related substances method defines the impurity profile that accompanies the potency result. Ask how impurities are identified, how the reporting, identification and limit thresholds were set, and whether individual and total impurities are reported separately. Where the material is bought as an intermediate, the limits that matter depend on the next synthetic step.

Residual solvents

Erythromycin thiocyanate is produced by fermentation followed by chemical processing, so residual solvents form part of the specification. Ask which solvents are in scope and how the list was derived from the process; the ICH Q3C guideline defines solvent classes. Then ask whether every batch is tested against the full list or on a defined frequency.

Documentation Controls

Documentation controls determine whether a delivered batch can be traced back to the records that produced it. A certificate of analysis is only useful if the batch number printed on it can be matched to a batch record, a retention sample and the label on the drum. The audit tests this by following one shipped batch end to end.

COA traceability

The certificate of analysis is lot-specific and is the primary evidence that a delivered batch meets specification. Confirm that it states the batch number, the test items, the methods, the results, the acceptance limits, and the assay basis. Two checks close the item: the batch number must match the drum label, and the certificate must be authorised by a named person rather than issued as an unsigned printout.

Batch records

The batch manufacturing record is the document set showing how a batch was made and tested. Buyers are not normally given the full record, but the audit should establish that it exists, that it is released by a second person, and that a redacted extract can be made available with the retention period.

Retention samples

A retention sample is material from a batch kept under defined conditions for a defined period, so a later question can be answered by re-testing rather than by recollection. Ask whether a sample is taken for every batch, where it is stored, and for how long. For material supplied as a powder in 20 KG drums, confirm the sample comes from the same homogenised material that filled the drums.

Supply Chain Transparency

Supply chain transparency establishes where the material is made, from what, and by whom. Three questions resolve it: the identity of the starting material, the identity of the manufacturing site, and whether any production step is subcontracted. The audit closes the gap by matching documents against each other, because they can be complete while naming a site that did not produce the material.

Starting materials

Erythromycin is fermentation-derived, and the specification for this material should name the salt form and its CAS number rather than the generic name alone. Erythromycin base (CAS 114-07-8), erythromycin stearate (CAS 643-22-1) and erythromycin ethylsuccinate (CAS 1264-62-6) are distinct materials with different molecular weights. Ask how the source is qualified, whether a change of source falls under change control, and which steps the TSE/BSE declaration covers.

Manufacturing site

Ask for the site name, the site address and the licence or registration the site operates under, then cross-check that information against the certificate of analysis and the GMP certificate. Where the material is repacked, relabelled or micronised before shipment, ask who performs that step, and where.

Subcontracting

Ask directly whether any step in the process is performed by a third party, and ask for the list of steps that are. Fermentation, isolation, drying, milling and packing are the steps to name explicitly, because a supplier may treat some of them as normal operations rather than subcontracting.

Audit Checklist Table

A supplier audit for erythromycin thiocyanate covers 50 items across four sections, each paired with the evidence that closes it and a verdict box. The table below is the checklist itself: 50 items across four sections, each paired with the evidence that closes it and a verdict box. Work through it in section order, record a verdict for every item, and keep the completed table as the audit record.

Section A — Quality system

#Check itemExpected evidenceVerdict
A1Quality unit independent of productionOrganisation chart plus authority to hold a batch☐ Met ☐ Partial ☐ Not met
A2GMP certificate covering the manufacturing siteCurrent certificate naming the producing site☐ Met ☐ Partial ☐ Not met
A3Certificate scope covering the operations performedScope covering fermentation, isolation, drying, milling and packing☐ Met ☐ Partial ☐ Not met
A4Quality manual or equivalent system documentControlled manual with revision number☐ Met ☐ Partial ☐ Not met
A5Documented change control procedureProcedure listing the change categories☐ Met ☐ Partial ☐ Not met
A6Customer notification before a change is implementedWritten commitment with a notification window☐ Met ☐ Partial ☐ Not met
A7Change impact assessment on the materialOne completed assessment for a real change☐ Met ☐ Partial ☐ Not met
A8Deviation handling procedureProcedure covering recording, investigation and closure☐ Met ☐ Partial ☐ Not met
A9Out-of-specification and out-of-trend procedureProcedure plus one investigation record☐ Met ☐ Partial ☐ Not met
A10Batch rejection, reprocessing and rework controlProcedure naming who authorises each decision☐ Met ☐ Partial ☐ Not met
A11Annual product quality review or equivalentPeriodic review report, or its documented index☐ Met ☐ Partial ☐ Not met
A12Complaint handling, returns and recall procedureProcedure with a mock recall record and timeframe☐ Met ☐ Partial ☐ Not met

Section B — Analytical capability

#Check itemExpected evidenceVerdict
B1Quality control laboratory identifiedLaboratory chart and the testing address☐ Met ☐ Partial ☐ Not met
B2Contract laboratory identified where testing is outsourcedContract laboratory name, scope and quality agreement☐ Met ☐ Partial ☐ Not met
B3HPLC system qualification and calibration recordsQualification records plus current calibration☐ Met ☐ Partial ☐ Not met
B4System suitability criteria written into each chromatographic methodMethod text stating the suitability parameters☐ Met ☐ Partial ☐ Not met
B5Microbiological assay capability for the potency resultAssay facility description and written method☐ Met ☐ Partial ☐ Not met
B6Reference standard identity, source and traceabilityReference standard certificate and re-test date☐ Met ☐ Partial ☐ Not met
B7Method validation or verification reports for release methodsValidation report per method☐ Met ☐ Partial ☐ Not met
B8Related substances method and impurity reporting approachMethod text plus the limit basis used☐ Met ☐ Partial ☐ Not met
B9Residual solvent testing approachSolvent list, limit basis and testing frequency☐ Met ☐ Partial ☐ Not met
B10Water content or loss on drying methodMethod text and a recent batch result☐ Met ☐ Partial ☐ Not met
B11Anhydrous basis calculation stated in the methodMethod text showing as-is to anhydrous conversion☐ Met ☐ Partial ☐ Not met
B12Stability-indicating capability of the assay and impurity methodsForced degradation data showing change is detected☐ Met ☐ Partial ☐ Not met

Section C — Documentation controls

#Check itemExpected evidenceVerdict
C1Batch-specific certificate of analysisA certificate for a named batch☐ Met ☐ Partial ☐ Not met
C2Certificate states test items, methods, results and limitsEach test shown with method and acceptance limit☐ Met ☐ Partial ☐ Not met
C3Certificate states the assay basisAnhydrous or as-is stated with the potency result☐ Met ☐ Partial ☐ Not met
C4Certificate carries the batch number and the manufacturing dateBatch number and dates on the document☐ Met ☐ Partial ☐ Not met
C5Certificate authorised by a named responsible personSignature and role of the authorising person☐ Met ☐ Partial ☐ Not met
C6Batch number on the certificate matches the drum labelDrum label text or photograph☐ Met ☐ Partial ☐ Not met
C7Specification document and test methods released to the buyerControlled specification with revision date☐ Met ☐ Partial ☐ Not met
C8Batch manufacturing record held for each batchRecord index plus a redacted extract☐ Met ☐ Partial ☐ Not met
C9Record retention period statedStated retention period and storage arrangements☐ Met ☐ Partial ☐ Not met
C10Retention samples held for each batchRetention sample policy and storage location☐ Met ☐ Partial ☐ Not met
C11Stability data and the assigned re-test periodStudy summary with conditions and duration☐ Met ☐ Partial ☐ Not met
C12Material safety data sheet for the material as suppliedCurrent MSDS with transport classification☐ Met ☐ Partial ☐ Not met
C13TSE/BSE statementDeclaration issued for this material☐ Met ☐ Partial ☐ Not met

Section D — Supply chain transparency

#Check itemExpected evidenceVerdict
D1Starting material identity statedSpecification naming salt form and CAS number☐ Met ☐ Partial ☐ Not met
D2Starting material sources qualifiedQualification record per source☐ Met ☐ Partial ☐ Not met
D3Change of starting material source under change controlProcedure plus a notification commitment☐ Met ☐ Partial ☐ Not met
D4Manufacturing site named and addressedSite name, address and licence or registration☐ Met ☐ Partial ☐ Not met
D5Documented site is the site that manufacturesWritten confirmation, cross-checked with the GMP certificate☐ Met ☐ Partial ☐ Not met
D6Steps performed at a second site identifiedProcess step list mapped to performing site☐ Met ☐ Partial ☐ Not met
D7Subcontracted steps disclosedSubcontracted steps with subcontractor names☐ Met ☐ Partial ☐ Not met
D8Quality agreement covering each subcontracted stepSigned agreement defining responsibilities☐ Met ☐ Partial ☐ Not met
D9Repacking or relabelling disclosedStatement of who repacks or relabels☐ Met ☐ Partial ☐ Not met
D10Batch traceability from shipment back to the batch recordOne worked example, drum label to batch record☐ Met ☐ Partial ☐ Not met
D11Transport and storage conditions carried through to shipmentShipping documents consistent with the MSDS☐ Met ☐ Partial ☐ Not met
D12Export documentation list confirmed before shipmentSupplier's export document list vs import requirements☐ Met ☐ Partial ☐ Not met
D13Quality agreement between buyer and supplierAgreement naming quality contacts on both sides☐ Met ☐ Partial ☐ Not met

Recording findings and closing the audit

Each item recorded as not met, or left open for want of a document, becomes a finding with an owner and a closure date. Findings are closed by receiving the document or by accepting a documented compensating control, not by a further assurance that the practice exists.

Separate them into two groups before deciding on qualification. Items affecting the material itself — the assay basis, impurity reporting, batch traceability and the identity of the manufacturing site — are normally resolved before a first order.

Frequently Asked Questions

Yes. A remote audit of documents, live interviews and screen-shared records can close the greater part of this checklist, and it is frequently the first stage of API supplier qualification. What it cannot verify is physical: storage conditions, material segregation and equipment condition. Where those items carry weight, plan an on-site visit before the first production order.

An erythromycin thiocyanate audit checklist should cover four domains: quality system, analytical capability, documentation controls and supply chain transparency. Within them it should address the site's GMP scope, change control and deviation handling, the microbiological bioassay and the basis of the potency result, certificate of analysis traceability, and whether the documented site produced the material.

No. A GMP certificate issued to a site confirms that the site was inspected against a GMP standard at a point in time. It does not confirm that the scope covers this material, that batch documentation is traceable, or that the assay basis matches the buyer's specification. A GMP audit is one input to API supplier qualification, not a substitute.

API supplier qualification is the overall decision to accept a supplier for a defined material and use, drawing on the specification review, sample evaluation, documentation review and audit. A supplier audit is one activity within it: a structured examination of systems and records against a checklist. Qualification can proceed with findings open where the buyer accepts them.

Request the specification and test methods, a recent batch certificate of analysis, the GMP certificate for the site, the material safety data sheet, the stability study summary and the TSE/BSE statement before the audit date. Reviewing them in advance turns the audit into a verification exercise.

The timeline is set by document turnaround and audit scheduling rather than by the checklist itself. The longest steps are sample evaluation, stability data review and any on-site visit. Buyers working to a delivery deadline should sequence the qualification steps backwards from that deadline.

Follow a risk-based interval rather than a fixed one. A supplier with an established history, no significant changes and a stable deviation record can be re-audited at a longer interval than a new supplier. A change of starting material source, site or major equipment triggers a re-audit independently of the interval.

Yes, a supplier may decline an on-site visit, and some will offer a remote audit instead. What matters is that the refusal is recorded and that the items an on-site visit would have closed are handled explicitly — by a third-party audit report, or by accepting the item as unresolved.

Findings that stop a qualification are those the buyer cannot compensate for: an inability to state which site manufactures the material, a certificate of analysis that cannot be traced to a batch record, an unstated assay basis, or the absence of a written method behind a reported potency result.

The audit report should contain the completed checklist with a verdict for every item, the evidence reviewed for each verdict, and a findings list giving each finding an owner and a closure date. It should also record the audit mode and the batches sampled.

Sources

  • PubChem, National Library of Medicine — compound records for erythromycin thiocyanate (CID 83938) and erythromycin (CID 12560)
  • DailyMed, National Library of Medicine — drug name index
  • ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients
  • ICH Q3C, Impurities: Guideline for Residual Solvents
  • Manufacturer specification data — CAS, molecular formula, molecular weight, anhydrous bioassay and packaging as supplied
Request an erythromycin thiocyanate specification and quotation

Send the salt form, the assay basis, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.

INFO@KINGWISH.CN