Erythromycin Thiocyanate at a Glance
Common nameErythromycin thiocyanate
CAS number7704-67-8
Molecular formulaC37H67NO13·HCNS (= C38H68N2O13S)
Molecular weight793.02
Pharmacopoeial statusIn-house specification — no monograph
Anhydrous bioassay≥755 u/mg, per in-house specification
Standard packaging20 KG / drum
GMP statusSite operates to GMP, as stated by the supplier
FDA registration numberNone
CEP numberNone

Erythromycin thiocyanate (CAS 7704-67-8) is the thiocyanate salt of the macrolide antibiotic erythromycin, molecular formula C37H67NO13·HCNS (equivalent to C38H68N2O13S), molecular weight 793.02. It is a different material from erythromycin base (CAS 114-07-8, molecular weight 733.94), erythromycin stearate (CAS 643-22-1) and erythromycin ethylsuccinate (CAS 1264-62-6), and the documentation described here is specific to the thiocyanate salt.

This page lists what accompanies each batch, how to read the certificate of analysis, and the regulatory identifiers the material does and does not hold. The two absent identifiers are stated as absent, together with the consequence for a buyer who needs a registration file.

Documents Supplied with Each Batch

Each batch of erythromycin thiocyanate is supplied with a batch-specific certificate of analysis; the wider package — MSDS, GMP certificate, specification document, stability data, TSE/BSE statement and residual solvent statement — is issued for the material and the manufacturing site as a whole. An erythromycin thiocyanate COA applies to one batch and is reissued for each new batch. The remaining documents describe the material and change only when the underlying data or the site itself changes.

A qualification file needs both categories. Material-level documents alone cannot show that the drums you received were released against specification; batch certificates alone cannot show that the site behind them operates to a quality system.

What each document contains, and who issues it

DocumentContentIssued by
Certificate of analysis (COA)Batch number, test items, methods, results, specification limits, release authorisationManufacturer's quality control function
Specification documentThe in-house specification the batch was released against, including the anhydrous bioassay of ≥755 u/mg per in-house specificationManufacturer
MSDSHandling, storage and transport classificationManufacturer or supplier
GMP certificateConfirmation that the manufacturing site operates to Good Manufacturing Practice, and the scope coveredHeld by the manufacturing site
Stability data summaryStorage conditions studied and the duration of supporting dataManufacturer
TSE/BSE statementDeclaration addressing transmissible spongiform encephalopathy riskManufacturer
Residual solvent statementSolvent classes present and the limits appliedManufacturer

What sits outside the standard package

Two categories fall outside it. Commercial and export documents — invoice, packing list, bill of lading, certificate of origin — are generated per shipment, in whatever format your destination customs authority requires. Registration support is separate again, and it is the item buyers tend to raise last. Whether the supplier will support a registration file for your market should be settled at enquiry stage, because the answer determines whether your filing is feasible on schedule.

Reading a COA

A certificate of analysis for erythromycin thiocyanate should state the batch number, the test items, the method used for each test, the result obtained, the specification limit that result was judged against, and the authorisation of the person who released the batch. A certificate that reports results without matching limits or methods cannot be used to judge conformance, because the reader cannot tell whether a number falls inside or outside the specification.

What should an erythromycin thiocyanate COA state?

FieldWhat it should state
Material identityErythromycin thiocyanate, CAS 7704-67-8
Batch numberThe specific batch the certificate applies to
Date of manufactureThe batch date
Test itemsThe parameters tested on that batch
MethodsThe method used for each test item
ResultsThe value obtained for each item
Specification limitsThe limit each result was judged against
ConclusionWhether the batch was released against specification
AuthorisationName or signature of the releasing person, and the date

Read the item list from the specification document rather than from the certificate. The certificate reports what was tested on one batch; the specification defines what the material requires.

Why the batch number comes first

Check the batch number on the certificate against the batch number on the drum label before the material is released. A mismatch is a traceability break, and it is cheaper to resolve before the drums are sampled than after. Where a shipment contains more than one batch, each batch needs its own certificate.

Why the methods matter as much as the results

Two laboratories can test the same material and report different numbers if they use different methods. The certificate states which method produced the result; your incoming-testing procedure states which method you will use. Where the two differ, the comparison you are making is between methods rather than between batches, and that difference belongs in qualification rather than at goods-in.

Why the assay basis has to be on the certificate

Erythromycin thiocyanate is released against an anhydrous bioassay of ≥755 u/mg, per in-house specification, and the anhydrous and as-is bases give different numbers for the same batch. A certificate that reports a bioassay result without stating the basis cannot be compared against a specification that states one. The receiving laboratory reads the number from the certificate, so a missing basis becomes an assumption.

GMP Status

The manufacturing site for erythromycin thiocyanate operates to Good Manufacturing Practice, as stated by the supplier. No certificate number and no issuing body are published here, because those details are not part of the material information released for publication. Buyers who need them for a qualification file should request the current certificate directly and receive it as a controlled document — a certificate number quoted second-hand, without the certificate behind it, is of no use to a reviewer.

What a GMP certificate does and does not cover

A GMP certificate covers a named site and a defined scope of activities. It confirms that the site was assessed against a Good Manufacturing Practice standard and that the assessed scope was found to comply. It does not confirm that any particular batch meets your specification, and it does not confirm that the material you are buying falls inside the assessed scope. Check the first against the certificate of analysis, and the second against the scope statement on the certificate.

What to verify in a GMP certificate

Confirm four things: site identity, scope, validity and traceability. The address must be the site that manufactured your batch, not a group headquarters or a different plant. The scope must include the manufacture and release of this class of material. The certificate must be current at the date of your review. Where you intend to rely on it in a filing, the certificate number must be verifiable with the issuing body. Raise any scope requirement at enquiry stage, since certificate scope varies between sites and a certificate that exists may not cover the scope your filing needs.

FDA and CEP Status

As supplied, erythromycin thiocyanate holds no FDA registration number and no CEP number. Both identifiers are absent, and that is stated plainly rather than left unmentioned. Buyers check these identifiers against public registers during due diligence, and a documentation set that implies a registration the material does not hold creates a discrepancy far more damaging than the absence itself.

Does erythromycin thiocyanate hold an FDA or CEP number?

No. There is no FDA registration number for erythromycin thiocyanate as supplied, and no Certificate of Suitability. A CEP is issued against a pharmacopoeia monograph, and this material is supplied to an in-house specification rather than to a monograph.

Why the absence is consistent with the material

The absence matches how the material is positioned: it is bought to a buyer-and-supplier specification, not against a published compendial standard. A search of the US DailyMed drug name index returns 21 product names containing "erythromycin" and none containing "thiocyanate". No monograph and no registration identifier are the same fact seen from two directions.

What the absence means for a buyer

Three consequences follow, and each is better handled before an order than after.

  • There is no existing registration to reference. Where a supplier holds a registration, a buyer can often lean on it within its own application. That option is unavailable here, so the data set supporting your application has to be assembled from the supplier's own documentation.
  • Your application carries the full data burden. Specification, methods, stability data, impurity information and the site's quality documentation become the substance of the filing rather than supporting material behind someone else's certificate.
  • The timeline is set by the route, not by the order. A registration file takes longer to prepare than a purchase order takes to fulfil. Establishing the route at enquiry stage lets the two run in parallel; establishing it after the supply agreement puts the filing on the critical path.

The master-file route when a registration file is required

Where a destination market requires a registration file, the mechanism normally used for an API of this type is a master-file submission — a VMF, a DMF or the equivalent instrument in that jurisdiction. The manufacturing site lodges the confidential process detail with the authority, and your application references that submission instead of reproducing it. The route requires the manufacturer's participation and cannot be assembled by the buyer alone.

Establish three things in writing at enquiry stage, before a supply agreement is signed: whether the supplier will support a master-file submission for the market in question; what form that support takes, and which party lodges it; and the timeframe, measured against your own filing schedule. A supplier who is willing but slow is a scheduling problem you can plan for. A supplier asked only after the agreement exists is a schedule risk with no fallback.

IdentifierStatus as suppliedConsequence
FDA registration numberNoneCannot be referenced in a filing; master-file route required
CEP numberNoneNo compendial route; supplied to an in-house specification
Pharmacopoeia monographNoneSpecification and methods come from the manufacturer
GMP statusSite operates to GMP, as stated by the supplierCertificate details to be requested directly

TSE/BSE Statement

A TSE/BSE statement is part of the standard documentation package for this material, and because the material is fermentation-derived and chemically processed rather than derived from animal tissue, it is issued as a declaration covering the manufacturing process. Confirm the form with the supplier before it is needed, so that a format your reviewer accepts is settled in advance rather than at the filing stage.

What a TSE/BSE statement addresses

The statement addresses transmissible spongiform encephalopathy risk in the supply chain. Where a material is animal-tissue-derived, the statement traces species and tissue of origin. Where it is not, it takes the shorter declaration form, confirming that the material is not animal-tissue-derived rather than tracing an origin that is absent from the route. Because the substance of the document is a statement of origin rather than a trace, it is material-level: it is reissued when the manufacturing route changes, not when a new batch is produced.

What a residual solvent statement covers

A residual solvent statement records the solvents used in manufacture and the limits applied to them, normally organised around the ICH residual solvent classification — Class 1 solvents, which are to be avoided; Class 2 solvents, which are limited; and Class 3 solvents, which carry lower toxicological concern. Read it alongside the specification: the statement establishes which classes are relevant to the route, and the specification carries the limits your incoming testing will check against.

How to word the documentation request

Name the document, the form and the destination. Requests phrased as a category rather than a list are usually answered with a question, which adds a round trip. Send a request in this shape:

For erythromycin thiocyanate, CAS 7704-67-8, please provide the batch certificate of analysis for each batch shipped; the in-house specification document; the MSDS; the current GMP certificate with its scope; the stability data summary and the assigned re-test interval; the TSE/BSE statement; and the residual solvent statement. Please also confirm whether you will support a master-file submission for our destination market, and on what timeframe.

Documentation Requests During Supplier Qualification

The TSE/BSE statement and the residual solvent statement are routinely requested during supplier qualification.

Retention and Traceability

Retention samples and batch records are held by the manufacturer so that a delivered batch can be re-examined after release, and the retention period and storage conditions applied to retained samples should be confirmed during supplier qualification. Retention exists to make a batch retrievable: an out-of-specification result found at your end can be investigated against retained material only if the manufacturer still holds a sample of the same batch under controlled conditions.

The buyer's side of traceability matters as much. Retaining your own reserve sample from each batch received lets you look again at the material as delivered, rather than as it now stands after storage on your site.

Batch records and retention samples

Batch records are the internal record of how a batch was made and released. They are held by the manufacturer rather than issued with the shipment, so the qualification question is not what they contain but whether they can be retrieved, and how quickly, if a batch is questioned. For retention samples, confirm the retention period, the quantity retained and the storage conditions. A period that expires before your own usage window closes leaves the batch unattributable if a question arises late.

Re-test interval and what to retain

The re-test interval is the period after which the material should be re-examined before further use. It is supported by the manufacturer's stability data and should be reconciled with your own storage conditions and with the time between receipt and use. Where your conditions differ from those studied, do the reconciliation during qualification rather than at the point of use.

Keep the complete document set for each batch, filed against the batch number alongside the reserve sample: the batch certificate of analysis, the specification document in force at the time of the order, the MSDS, the GMP certificate current at the time of the order, the stability data summary, the TSE/BSE statement and the residual solvent statement. Filing by batch rather than by document type pays back at audit, when a reviewer asks about one batch and expects one folder.

Frequently Asked Questions

Yes. Certificates of analysis are issued per batch; request the batch CoA with the shipment, so it is available at goods-in rather than after arrival. Confirm at order stage whether the certificate travels as a printed document with the drums or is issued electronically.

A certificate of analysis reports the results obtained on one specific batch, against the limits they were judged against. A specification is the standing document that defines which test items apply to the material and what the limits are, and it does not change from batch to batch. You need both: the specification tells you what to expect, and the certificate tells you what was found.

Yes. An erythromycin thiocyanate MSDS is part of the standard documentation package, and it states the handling precautions, storage conditions and transport classification for the material — confirm the current version with the supplier. Request it before the shipment is booked rather than on arrival, because the transport classification affects how the shipment is declared.

Yes. A TSE/BSE statement is part of the standard documentation package for this material. Because the material is fermentation-derived and chemically processed rather than animal-tissue-derived, it is issued as a declaration covering the manufacturing process. Confirm the form of the declaration if your reviewer requires a specific format.

A residual solvent statement records the solvents used in manufacture and the limits applied to them, normally organised around the ICH residual solvent classification. It is a material-level document and should be read alongside the specification, which carries the limits your incoming testing will check.

The manufacturing site operates to Good Manufacturing Practice, as stated by the supplier. The certificate itself should be requested directly and received as a controlled document, so that the site name, the scope of activities covered and the validity date can be verified against the batch you are buying.

No. As supplied, erythromycin thiocyanate holds neither an FDA registration number nor a CEP number. This is consistent with the material being supplied to an in-house specification rather than to a pharmacopoeia monograph. Buyers who need a registration file should establish a master-file route with the supplier at enquiry stage, before a supply agreement is signed.

Format requirements vary by buyer and by destination market, and a template from your own quality system is the clearest way to communicate them. Send the template with the documentation request at enquiry stage, together with the test items your specification requires, so that format and content are settled before the first batch is released.

Sources

  • PubChem, National Library of Medicine — compound records for erythromycin thiocyanate (CID 83938), erythromycin (CID 12560), erythromycin stearate and erythromycin ethylsuccinate
  • DailyMed, National Library of Medicine — drug name index
  • Manufacturer specification and documentation data — in-house specification, anhydrous bioassay, packaging configuration, GMP status and documentation scope as supplied
Request an erythromycin thiocyanate specification and quotation

Send the salt form, the assay basis, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.