Erythromycin Thiocyanate at a Glance
Common nameErythromycin thiocyanate
CAS number7704-67-8
Molecular formulaC37H67NO13·HCNS (= C38H68N2O13S)
Molecular weight793.02
Form as suppliedPowder
Standard packaging20 KG / drum
Pharmacopoeial statusIn-house specification — no pharmacopoeia monograph
Anhydrous bioassay≥755 u/mg, per in-house specification
GMP statusSupplier-stated; certificate to be verified
FDA registration numberNone
CEP numberNone
Related salt formsErythromycin base CAS 114-07-8, MW 733.94; stearate CAS 643-22-1, MW 1018.4; ethylsuccinate CAS 1264-62-6, MW 862.06
Supplied asA pharmaceutical intermediate and veterinary-grade API

Erythromycin thiocyanate (CAS 7704-67-8) is the thiocyanate salt of the macrolide antibiotic erythromycin, with the molecular formula C37H67NO13·HCNS (equivalent to C38H68N2O13S) and a molecular weight of 793.02. It is supplied as a powder in 20 KG drums, and is bought both as a pharmaceutical and veterinary material and as a macrolide intermediate. This page is a buyer-side evaluation framework for the erythromycin thiocyanate manufacturers and suppliers behind a quotation: what a production site has to be able to do, which documents to request, which specification points decide whether two quotations describe the same material, and which quotation patterns warrant a follow-up question.

At a Glance

What This Page Covers

Evaluating an erythromycin thiocyanate supplier comes down to six areas: the type of manufacturer behind the material, the capabilities the production site holds, the documents it can issue, the specification basis it quotes against, the transparency of its supply chain, and the terms it offers. It covers the manufacturer types behind the material, the capabilities a production site has to hold, the documents to request, the specification points that decide whether two quotations are comparable, and the quotation patterns that call for a follow-up question.

What evaluating a supplier means here

In one line: a structured way to decide whether an erythromycin thiocyanate supplier can meet your specification, your documentation requirement and your delivery timeline before you commit to an order.

It is not a single check but a set of checks against a written standard you define, applied in the same form to every candidate.

How Supplier Identity Is Handled

Supplier identity and plant ownership change over time; this page therefore sets out the evaluation criteria instead of a fixed list of names. Company names are not published here. Prices are not quoted either, because quotations for this material depend on assay basis, impurity profile, documentation scope, packaging configuration and order quantity.

Who Manufactures Erythromycin Thiocyanate

Erythromycin thiocyanate is manufactured by two broad types of producer: fermentation-based API plants that run the macrolide route through to an isolated thiocyanate salt, and intermediate-focused producers that make the salt as a defined intermediate for downstream chemistry. Both types can supply commercial quantities; they differ in what they are organised to support.

The two manufacturer types

A fermentation-based API plant runs the macrolide route from the fermentation stage onward, converts erythromycin to the thiocyanate salt, isolates and dries the solid, and releases it against an in-house specification. It is built around lot-to-lot consistency at production scale and holds the analytical laboratory that goes with a released material.

An intermediate-focused producer makes the salt as a defined intermediate rather than a finished pharmaceutical material. That type of site is organised around delivering to a customer's specification for a downstream step, and supports the impurity limits that matter for the next synthetic transformation.

A buyer qualifying a finished material is judging documentation depth and stability history; a buyer qualifying an intermediate is judging specification-to-specification repeatability. The same supplier can fit one profile well and the other poorly, which is why evaluation criteria belong before the candidate list is built.

Manufacturer, factory and trading supplier — why the label matters

A manufacturer makes the material; a trading supplier sells it. For a material with no pharmacopoeia monograph, the entity that holds the specification, the batch records and the analytical methods can answer technical questions about them.

Many buyers work through trading suppliers by choice, for consolidated shipping, credit terms or multi-product ordering. What matters is knowing which entity in the chain is the manufacturing site, since that is the entity an audit visits. Three questions establish it: which site manufactures the batch, whether that site appears on the GMP certificate, and whether the specification document was issued there.

Where the production base sits

China is a significant production location for macrolide antibiotics, and erythromycin thiocyanate is produced there at commercial scale. The material sits near the start of a route that leads to several semi-synthetic macrolides, including clarithromycin (CAS 81103-11-9), azithromycin (CAS 83905-01-5), azithromycin dihydrate (CAS 117772-70-0) and roxithromycin (CAS 80214-83-1).

There is no pharmacopoeia monograph for erythromycin thiocyanate: a search of the US DailyMed drug name index returns 21 product names containing "erythromycin" and none containing "thiocyanate". With no public monograph, the manufacturer's own specification document and test methods carry more weight, not less.

What a Manufacturing Site Has to Be Able to Do

A site that produces erythromycin thiocyanate has to run the fermentation route, convert erythromycin to the thiocyanate salt, isolate and dry the solid, and release the batch against an in-house specification. Each of those capabilities is observable and can be verified with a document or an audit question.

Fermentation and salt conversion

Erythromycin is fermentation-derived, so the site needs fermentation capacity, seed preparation and the recovery steps that go with them. The evaluation question is whether fermentation is run in-house or bought in as a starting material, because that determines which part of the route the site can control and describe.

Converting erythromycin to the thiocyanate salt is a defined chemical step, and the isolation and drying that follow determine the physical form of the delivered material. Ask how the conversion is controlled, how the salt form is confirmed on each batch, and what the batch record holds.

Drying, milling and powder handling

The material is supplied as a powder, so drying and particle-size control sit directly on the delivery specification. An erythromycin thiocyanate powder manufacturer controls final water content and particle-size distribution as release parameters rather than incidental outcomes, and can state which of the two is the tighter constraint for a given customer.

Particle size affects flow, blending and dissolution downstream and is set by the milling and classification steps rather than by the chemistry. A site that can describe its own particle-size control runs the finishing steps itself — the question to put to an erythromycin thiocyanate powder factory that has not stated whether drying and milling are run in-house.

The analytical laboratory and quality system

The laboratory has to run the microbiological assay used for potency, the chromatographic methods used for related substances, and the methods for residual solvents and water content. Ask which methods are run in-house and which are sent out, since an outsourced method adds a turnaround step to every release.

The manufacturing site is stated by the supplier to be GMP-certified. Confirm that the certificate covers the site that actually produces the batch and that it is current at the time of the order, since certificate scope varies between sites.

How to Evaluate a Supplier

Evaluate an erythromycin thiocyanate supplier on six areas: manufacturing capability, quality system, documentation, specification, commercial reliability and traceability. Each area has a defined set of requests, and each request exists to establish something specific.

Evaluation areaWhat to ask forWhat it establishesWhy it matters
Manufacturing capabilitySite identity; fermentation and conversion steps run in-house; capacity rangeWhether the site controls the route it is sellingDetermines who answers technical questions and who an audit visits
Quality systemCurrent GMP certificate covering that site; change control; deviation and batch-review practiceWhether release decisions follow a written systemA certificate that does not cover the producing site establishes nothing about the batch
DocumentationCertificate of analysis; specification document and test methods; MSDS; stability summary; TSE/BSE and residual solvent statementsWhether the material can be qualified and cleared for your destinationDocumentation scope affects the quotation, the lead time and the filing route
SpecificationAssay basis stated explicitly; related substances; residual solvent data; particle sizeWhether the offered material matches your specificationTwo quotations can both read "≥755 u/mg" and still describe different materials
Commercial reliabilityLead time with its dependencies; minimum order quantity policy; packaging; export document setWhether supply can be scheduled and clearedDelays usually trace to an unstated parameter rather than to production
TraceabilityBatch number on the certificate against the batch number on the drum labelWhether lot traceability holds from release to receiptA mismatch is a traceability break and has to be resolved before release

The six areas above are the evaluation criteria. The order in which they are worked through — enquiry, sample, documentation review, audit and first order — is the purchasing sequence, and it is set out step by step on the sourcing erythromycin thiocyanate from China page.

Documentation to Request

Request the certificate of analysis, the GMP certificate, the material safety data sheet, stability data, a TSE/BSE statement and a residual solvent statement, together with the specification document and the test methods behind it. Raise the full list at enquiry stage rather than after price agreement, because documentation scope affects both the quotation and the lead time.

DocumentWhat it should stateWhat the reviewer is checking
Certificate of analysisBatch number, test items, methods, results, specification limitsThat the batch number matches the drum label and the methods match the specification
Specification documentSalt form by name and CAS, assay basis, release parameters with limitsThat the salt form is explicit and the assay basis unambiguous
GMP certificateSite name and address, scope, validity datesThat it covers the site that produced the batch and is current
MSDSHandling, storage conditions, transport classificationThat storage and transport requirements match your receiving site
Stability dataStudy conditions, duration, tested parameters, assigned re-test periodThat the supporting data covers the storage conditions you will use
TSE/BSE statementForm of the declaration and its basisThat the declaration is on file and covers the material supplied
Residual solvent statementSolvent classes present and the limits appliedThat limits are stated against a defined framework and met on the batch

Certificate of analysis

The certificate of analysis is lot-specific and is the primary evidence that a delivered batch meets specification. It should carry the batch number, test items, methods used, results and the specification limits the results were judged against. Check the batch number against the drum label; a mismatch is a traceability break and should be closed before release.

GMP certificate

The GMP certificate, once obtained and verified, establishes that the manufacturing site operates to Good Manufacturing Practice. Confirm that it names the site that manufactures the material and that the validity dates cover your order schedule. Where your destination market requires a specific GMP scope, raise it at enquiry stage.

Material safety data sheet

The MSDS establishes handling requirements, storage conditions and transport classification. Request it before the shipment is booked rather than on arrival, and reconcile the storage conditions against what your own site can hold from receipt to release.

Stability data

Stability data establishes the basis for the shelf life or re-test period assigned to the material. Request the study summary rather than only the assigned period, so that the storage conditions and the duration of the supporting data are both visible.

TSE/BSE statement

The TSE/BSE statement addresses transmissible spongiform encephalopathy risk. Erythromycin thiocyanate is a fermentation-derived and chemically processed material rather than an animal-tissue-derived one, so the statement is issued as a declaration covering the manufacturing process. Confirm who issues it and in what format.

Residual solvent statement

The residual solvent statement identifies which solvent classes are present and which limits apply. Residual solvent limits are normally expressed against the solvent classes defined in the ICH Q3C guideline. Ask whether it is a declaration about the route or a set of batch results: only the second tells you what was found in the lot.

Specification document and test methods

There is no pharmacopoeia monograph for erythromycin thiocyanate, so the manufacturer's specification document is the reference point for the material. Request it with the test methods and review both against your own incoming-testing procedures, establishing method equivalence before the first order rather than at goods-in.

Specification Comparison Points

Compare quotations on five specification points: assay basis, related substances, residual solvents, particle size and the salt form itself. Two quotations can carry the same headline assay figure and still describe materials that differ on one or more of these points.

Assay basis — anhydrous versus as-is

Erythromycin thiocyanate is assayed by microbiological assay and reported in units per milligram, and the anhydrous basis and the as-is basis give different numbers for the same lot. A specification that states "≥755 u/mg" without naming the basis can be read two ways, and the two readings do not describe the same material.

The ≥755 u/mg figure is an in-house specification for this material, not a pharmacopoeia limit, and it should be supplied as `per in-house specification`. Write the basis explicitly into your specification document and confirm in the quotation which basis the offered material meets.

Related substances

Related substances describe the impurity profile carried by the batch, and the limits that matter depend on what happens to the material next. A finished-product buyer looks at the profile against the specification limits; an intermediate buyer looks at the impurities that carry into the next synthetic step.

Residual solvents

Residual solvent data states which solvent classes are present and at what level relative to the applicable limits. Compare the solvents listed against the manufacturing route the supplier describes, since a route that uses an unlisted solvent leaves a gap in the comparison.

Particle size

Particle size affects flow, blending and dissolution behaviour downstream, and it is set by the finishing steps rather than by the chemistry. Ask for the distribution rather than a single figure, and whether it is a release parameter or a monitored value.

Salt form and identity

Confirm the salt form by name and CAS number in the specification, not by the word "erythromycin" alone. At least three commercially distinct materials carry that name.

MaterialCASMolecular weight
Erythromycin base114-07-8733.94
Erythromycin thiocyanate7704-67-8793.02
Erythromycin stearate643-22-11018.4
Erythromycin ethylsuccinate1264-62-6862.06

Because the molecular weights differ — 733.94 for the base against 793.02 for the thiocyanate — a mass-based specification written for one cannot be carried across to the other. Where a specification was copied from a document written for a different salt, the conversion factors, assay basis and solubility expectations need to be re-derived rather than reused.

Red Flags in a Quotation

A quotation that leaves the assay basis unstated, refers to a specification without providing the document, or answers a technical question with a commercial reply is not yet a quotation you can compare. Each pattern below is a question to ask, not a conclusion about the supplier.

An assay figure with no stated basis

Ask which basis the figure refers to and request the certificate of analysis that carries it. The answer is normally available within one exchange.

A specification with no document behind it

A specification quoted in prose cannot be checked line by line. Ask for the specification document; where no shareable document exists, that itself says something about how the supplier holds its own specifications.

The salt form given as "erythromycin"

Where the material is described only as "erythromycin", the salt form is unconfirmed. Ask for the CAS number in writing — one question that removes a category of comparison error at the outset.

Documentation scope appearing after the price

Where a document requirement is raised only after a price is agreed, the quotation may need to be reissued. That is a sequencing issue rather than a supplier issue, resolved by sending the full document list with the first enquiry.

A lead time with no dependencies stated

Ask whether the figure assumes stock or a new production run, and whether it assumes the standard export document set. The answer changes what the figure means for your schedule.

Pricing answers to specification questions

Where a specification question receives a price response, the technical question is still open. Restate it. On a material with no pharmacopoeia monograph, the specification conversation has to complete before the commercial one is meaningful.

Frequently Asked Questions

Verification rests on six areas: manufacturing capability, quality system, documentation, specification, commercial reliability and traceability. Establish which entity is the manufacturing site, request the specification document, the GMP certificate and a recent certificate of analysis, and compare offers on assay basis, related substance limits, residual solvents and particle size before treating two quotations as comparable. The order in which those checks are run — enquiry, sample, documentation review, audit and first order — is set out on the sourcing erythromycin thiocyanate from China page.

An erythromycin thiocyanate manufacturer has to run the fermentation route, convert erythromycin to the thiocyanate salt, isolate and dry the solid, and release the batch against an in-house specification. With no pharmacopoeia monograph, the manufacturer's own specification document and test methods are the reference point for what the material is.

An erythromycin thiocyanate factory audit should cover fermentation and salt conversion, drying and particle-size control, the analytical laboratory and its method set, the quality system and GMP certificate scope, and change control. Confirm that the certificate covers the site being audited.

An erythromycin thiocyanate powder manufacturer controls drying, milling and particle-size distribution as release parameters, because the material is delivered as a powder. An intermediate-focused producer is organised around delivering a defined intermediate to a downstream specification.

Request the certificate of analysis, the specification document and test methods, the GMP certificate, the MSDS, a stability study summary, a TSE/BSE statement and a residual solvent statement. Raise the full list at enquiry stage rather than after price agreement.

Erythromycin thiocyanate is supplied to an anhydrous bioassay of ≥755 u/mg, per in-house specification. Because the anhydrous and as-is bases give different results for the same lot, the basis should be stated explicitly in the specification document and confirmed in the quotation.

Yes. Many buyers purchase through trading suppliers for consolidated shipping, credit terms or multi-product ordering. What matters is knowing which entity is the manufacturing site, since that is the entity an audit visits and that the GMP certificate has to cover. As supplied, the material holds neither an FDA registration number nor a CEP number, and standard packaging is 20 KG per drum.

Sources

  • PubChem, National Library of Medicine — compound records for erythromycin thiocyanate (CID 83938), erythromycin (CID 12560), erythromycin stearate, erythromycin ethylsuccinate, clarithromycin, azithromycin, azithromycin dihydrate and roxithromycin
  • DailyMed, National Library of Medicine — drug name index
  • ICH — Q3C guideline, residual solvent classification
  • Manufacturer specification data — CAS, molecular formula, molecular weight, anhydrous bioassay and packaging as supplied
Request an erythromycin thiocyanate specification and quotation

Send the salt form, the assay basis, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.