| CAS number | 1208319-27-0 |
|---|---|
| Molecular formula | C19H27N5O6S |
| Molecular weight | 453.51 |
| Free base | CAS 1208319-26-9 · 337.44 |
| Standard | In-house specification |
| Packaging | 1 KG / bag |
| Application | Chewable tablets |
| GMP | Yes |
| FDA / CEP | None |
Oclacitinib maleate (CAS 1208319-27-0) is priced per order rather than against a published list, and the figure a supplier quotes depends on four variables: the specification the order is quoted against, the documentation scope, the packaging and the volume. Two quotations for the same nominal material are not comparable until those four are aligned. This guide sets out how the cost of an oclacitinib maleate order is built, what to fix in the enquiry so that quotations can be compared, and how to run the order once a supplier is chosen.
The cost of an oclacitinib maleate order sits in the specification, the documentation scope, the packaging and the volume, in roughly that order of impact. None of the four appears in a quotation that states only a price per kilogram, which is why such quotations cannot be compared.
For a material with no pharmacopoeia monograph, the specification is not an inherited document — it is written by the buyer or adopted from the supplier. Whichever way it happens, the limits inside it determine how much analytical work, how much process control and how many rejected batches stand behind the quoted figure. The quotation is a summary of those decisions, whether or not the buyer made them consciously.
Specification stringency comes first because it is the only variable that changes the manufacturing process rather than the transaction around it. A tighter individual impurity limit, an additional named impurity, a narrower particle-size distribution or a second polymorphic form specification each requires more control at the site.
Documentation scope comes second. A standard package and an expanded package that adds a method transfer, a stability summary and a regulatory support letter are different deliverables, and the second costs more to produce because it consumes analytical and regulatory time.
Packaging comes third, and for this material it is not a logistics detail. Oclacitinib maleate is documented as sensitive to light, so the barrier that protects it is part of the specification. A cheaper container that does not provide the barrier is a cheaper product, not a cheaper version of the same product.
Volume comes last, and it works in both directions. Larger volumes spread fixed costs — the analytical release work, the setup, the documentation — across more material. But volume also moves the order from stock to scheduled production, which changes the commercial relationship rather than merely the unit cost.
A published price list exists where the material is a commodity with a stable specification, multiple interchangeable producers and a liquid market. Oclacitinib maleate meets none of those conditions: the specification is in-house and varies between suppliers, the manufacturing base is narrow and constrained by the patent position.
The absence of a list price is therefore informative rather than obstructive. It tells the buyer that the specification is doing real work and that the enquiry has to carry the requirement.
The buyer controls the specification, the documentation scope, the packaging requirement and the order profile. Those four are the whole of the buyer's cost lever, and three of them can be fixed before the first enquiry is sent.
The specification is the only one that requires technical judgement, because it trades cost against downstream risk. A looser limit is cheaper to buy and more expensive to discover late. The other three are administrative: state them, and the quotations become comparable.
Oclacitinib maleate is released against an in-house specification, and the limits inside that document are the primary driver of what the material costs to make. A buyer who adopts the supplier's specification uncritically has accepted the supplier's cost position along with it.
The specification also determines what the buyer will test, what the buyer will reject, and what the buyer's own regulatory file will have to support. It is worth spending an analytical review on before the enquiry rather than after the first delivery.
Identity testing confirms that the material is oclacitinib maleate and not the free base or another salt of the same molecule. The free base carries CAS number 1208319-26-9 and a molecular weight of 337.44; oclacitinib maleate carries CAS number 1208319-27-0 and a molecular weight of 453.51.
The assay figure must state two things in the same line: the value and its basis. The basis question has two dimensions — salt versus base, and anhydrous versus as-is — and a figure that omits either cannot be compared with a figure that states both. This is the most common cause of a specification dispute at goods-in, and it costs nothing to prevent.
The related-substances specification for a salt has to cover both the API-derived impurities and the counter-ion. For oclacitinib maleate that means the oclacitinib-related impurities, individually and in total, alongside the maleic acid content that confirms the salt stoichiometry.
A related-substances method written for the free base will not describe the salt completely. Where a specification has been adapted from a free-base dossier, the adaptation is worth checking, because the gap it leaves is analytical rather than commercial and neither party notices until a review.
Residual solvents are classified and limited under the ICH Q3C framework. A specification that states compliance with the framework without stating which solvents the process uses has not told the buyer enough to assess it.
Elemental impurities sit under ICH Q3D, which is a risk-assessment framework rather than a single limit. Acceptable levels are derived per element from the route of administration and the maximum daily dose, and a specification stating one "heavy metals" figure does not demonstrate conformity with the framework. For an oral dosage form the assessment is available and is a reasonable request.
Particle-size distribution and bulk density determine whether the material blends, flows and compresses the way the downstream process was designed. Neither appears in every in-house specification by default, and both are legitimate additions.
The cost impact is real but one-sided: adding a particle-size specification to the purchase specification raises the supplier's control burden and therefore the price, while omitting it transfers the risk to the buyer's process. Which side of that trade to take depends on how much formulation work the buyer controls.
The documentation package separates into a standard set that accompanies every batch and an extended set that is produced for the material or the site. Knowing which is which prevents paying twice for documents already included, and prevents discovering a gap after the order.
Documentation is the part of an API purchase that outlasts the transaction. A batch is consumed; the certificate, the methods and the stability summary remain in the buyer's file and are read again during an audit or a regulatory review years later.
Every batch of oclacitinib maleate is accompanied by a batch-specific certificate of analysis, and the wider set — specification document, analytical methods, material safety data sheet, GMP certificate, stability data summary, TSE/BSE statement and residual solvent statement — is issued for the material and the manufacturing site as a whole.
That split matters at ordering. The batch certificate is reissued for each batch; the material-level documents change only when the underlying data or the site changes. A buyer who requests "all documentation with each batch" is asking for the material-level set to be reissued unnecessarily, and a supplier that agrees to do so is signalling that it has not understood the distinction.
Three items in the extended set carry real cost: a method transfer package, a regulatory support letter and an audit. The first two are analytical and regulatory work; the third is time at the site and at the buyer.
None of the three is needed for every buyer. A distributor who resells sealed drums may need none of them. A finished-product manufacturer preparing a registration dossier will usually need all three, and should state that requirement in the enquiry rather than after the quotation.
The cheapest place to find a documentation gap is in the quotation round. Asking for a specimen batch certificate and the specification document before an order costs nothing and reveals whether the supplier can produce the set.
The check is simple: the specification names the limits, and the certificate should quote the same limits, for the same test items, with the same revision. Where the two do not line up, the documentation is assembled rather than generated, and the discrepancy will not improve after an order is placed.
A qualified supplier checklist for oclacitinib maleate has to cover more than the commercial terms, because the material has no compendial monograph and the supplier's own documents are the quality reference. The checklist below is organised around what the buyer can verify rather than what the supplier can assert.
The list is deliberately short. A checklist with forty items gets filled in without being read; a checklist with twelve items that each require a document gets used.
| # | Item | Evidence |
|---|---|---|
| 1 | Legal entity that manufactures, named | Site name and address on the GMP certificate |
| 2 | GMP certificate with scope | Certificate copy, scope matched to the material |
| 3 | Specification document by revision | Document, not a summary |
| 4 | Analytical methods for each test item | Method documents matching the certificate codes |
| 5 | Specimen batch certificate with batch number populated | A real batch, not a template |
| 6 | Assay basis stated, salt or base and anhydrous or as-is | Written into the specification |
| 7 | Related-substances limits, individual and total | In the specification, with the method |
| 8 | Residual solvent statement by class | Statement against ICH Q3C |
| 9 | Elemental impurity assessment | Assessment against ICH Q3D |
| 10 | Stability summary and assigned re-test period | Data duration and conditions |
| 11 | Packaging barrier suitable for a light-sensitive material | Container description |
| 12 | Traceability from drum label to certificate | Batch numbering convention |
Three things sit outside the checklist because they are assessed rather than verified: the supplier's responsiveness, the quality of its answers and the coherence of its documentation as a set. Each of those is a judgement, and judgements are best recorded in writing at the time they are formed.
The remaining gap is the site audit. A checklist confirms that documents exist; an audit confirms that the system which generated them is operating. For a first order from an unfamiliar supplier, the two together are the qualification.
A qualified supplier does not stay qualified by default. Specifications are revised, sites change ownership, methods are updated and people leave. The checklist should be tied to the revision numbers it was completed against, so that a revision change triggers a review rather than passing unnoticed.
The practical mechanism is to record, for each supplier, the specification revision, the GMP certificate expiry date and the date of the last certificate reviewed. Those three dates are the whole of the maintenance burden, and they are enough to prompt a review before a gap becomes a problem.
An oclacitinib maleate order is defined by the specification, the quantity, the packaging and the delivery terms, and each of the four should appear in the purchase order in the same terms as in the quotation. The order is where the specification stops being a negotiation and becomes a contract.
Packaging for this material is specification-relevant rather than logistical. Oclacitinib maleate is documented as sensitive to light and to acid, and is supplied in 1 KG bags; the barrier that protects it during storage and transport is part of what the buyer is buying.
The purchase order should restate the full identity — oclacitinib maleate, CAS 1208319-27-0 — rather than the molecule name alone, and should reference the specification document by revision. It should state the quantity, the packaging format, the documentation to accompany the shipment and the delivery terms.
Restating the identity is not pedantry. A purchase order written for "oclacitinib" leaves open which salt was bought, and a supplier that ships the free base has supplied something that matches the order as written. The CAS number closes that gap.
Delivery terms determine where the price changes hands and where risk transfers from the supplier to the buyer. Terms of sale and Incoterms should be stated in the enquiry, because a price quoted on one set of terms cannot be compared with a price quoted on another.
The origin port and the destination requirements are worth fixing early. Export documentation requirements differ by destination, and a mismatch between the document set and the destination requirement is the most common reason a shipment is held.
Order timelines depend on whether the material is quoted from stock or from a scheduled production run, on the analytical release work required by the specification, and on the documentation scope requested. Those three are stated in the enquiry or they are discovered later.
For a first order from a new supplier, add the qualification time — documents reviewed, sample tested, audit if required — to whatever commercial timeline is agreed. The two run in sequence, and treating them as one is how timelines slip.
Two quotations for oclacitinib maleate are comparable when six items line up: the specification reference, the assay basis, the packaging, the documentation scope, the price validity period and the delivery terms. Where any of the six differs, the prices are for different products.
Comparing on price alone is not a shortcut; it is a different exercise. The buyer is then choosing between scopes, and choosing between scopes without knowing which is which is how a purchase that looked cheaper becomes the more expensive one.
A comparison sheet with one row per supplier and one column per item makes the differences visible before the numbers are read. The six columns above, plus a column for the price, is the whole of the sheet.
Where a supplier leaves a cell blank, the blank is the finding. A supplier that cannot state its assay basis has not quoted against a specification; a supplier that cannot state its documentation scope has not priced the same deliverables.
The lowest figure is the cheapest order when the scope is identical and the supplier is qualified. Failing either condition, the lowest figure is a price for something else.
The qualification condition is the one buyers discount most often. A supplier that clears every gate but quotes higher is offering a comparable product at a higher price. A supplier that quotes lower but fails a gate is offering a material the buyer cannot use in a commercial filing, at any price.
Send the salt form, the assay basis, the dosage form, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.