| CAS number | 1208319-27-0 |
|---|---|
| Molecular formula | C19H27N5O6S |
| Molecular weight | 453.51 |
| Free base | CAS 1208319-26-9 · 337.44 |
| Standard | In-house specification |
| Packaging | 1 KG / bag |
| Application | Chewable tablets |
| GMP | Yes |
| FDA / CEP | None |
Oclacitinib maleate (CAS 1208319-27-0) is the maleic acid salt of oclacitinib, supplied as a veterinary API to an in-house specification and packed in 1 KG bags. Its molecular formula is C19H27N5O6S and its molecular weight is 453.51. This guide covers the salt form, the specification a buyer should quote against, the documentation package, the sourcing route from China and the factors that move a quotation.
Oclacitinib maleate is a Janus kinase (JAK) inhibitor supplied as an active pharmaceutical ingredient for formulation into chewable tablets. It is identified by CAS number 1208319-27-0, molecular formula C19H27N5O6S and molecular weight 453.51.
The name carries three separate pieces of information. "Oclacitinib" is the International Nonproprietary Name of the base molecule. "Maleate" names the counter-ion — maleic acid — that forms the salt. And the CAS number fixes which of the two commercial forms of the molecule is being bought, because the free base carries a different CAS number and a different molecular weight.
Oclacitinib is the International Nonproprietary Name. The originator product is marketed by Zoetis under the brand name Apoquel™, and buyers frequently arrive at this material by searching for the brand and working backwards to the active substance.
That route works because the brand name and the INN describe the same molecule at different levels of the supply chain. A brand name identifies a finished, registered product and the company that holds its marketing authorisation. The INN identifies the active substance, and it is the INN that appears on a specification, a certificate of analysis and a customs declaration. A purchase order written against a brand name transfers none of the documentation that a purchase order written against the INN and its CAS number carries.
Oclacitinib maleate is an API, not a finished product. It is supplied as a powder and formulated downstream into the finished dosage form — in this case a chewable tablet — by a manufacturer holding the relevant registration for the destination market.
That distinction matters at the purchasing stage. The API supplier's responsibility ends at the drum: identity, assay, impurity profile, residual solvents, physical form and the documentation package that travels with the batch. The finished-product manufacturer carries the formulation work, the registration file and the clinical claims. A specification written at the API level should therefore describe the material, not the finished product.
Oclacitinib maleate is not the free base. The free base is a separate commercial entity with CAS number 1208319-26-9, molecular formula C15H23N5O2S and molecular weight 337.44. The two differ by the maleic acid moiety and by 116.07 in molecular weight.
Nor is it interchangeable with other JAK inhibitors. Tofacitinib, baricitinib, upadacitinib and the other members of the class each carry their own CAS number, molecular formula and impurity profile, and each is supplied to its own specification. The class shares a mechanism; it does not share a specification.
Oclacitinib is supplied commercially as the maleate salt because the salt form is what the finished dosage form was developed against. A buyer specifying the free base is specifying a different material, and a mass-based formula or limit written for one cannot be carried across to the other without recalculation.
The arithmetic is straightforward and worth doing once. Maleic acid (CAS 110-16-7, molecular formula C4H4O4) has a molecular weight of 116.07. Adding that to the free base value of 337.44 gives 453.51, which is the molecular weight of the salt. The ratio between the two — 453.51 divided by 337.44, or 1.3439 — is the conversion factor between a quantity expressed as the salt and the same quantity expressed as the base.
A potency figure is meaningless without its basis. The same number on a certificate of analysis can mean that percentage of the salt or that percentage of the base, and the two readings differ by more than a third of the stated weight.
This is the single most common source of specification dispute at goods-in. Two suppliers can both quote a purity figure and deliver materials that are not equivalent, because one expressed the result against the salt and the other against the base. The remedy costs nothing: write the basis into the purchase specification, in the same line as the figure.
The salt form determines more than the arithmetic. It determines solubility behaviour in the formulation solvent system, the crystalline form the material is supplied in, and therefore the particle-size and flow characteristics the downstream process has to work with.
Oclacitinib maleate is also documented as sensitive to acid and to light. A published forced-degradation study on the API found degradation products generated under acidic conditions and under light exposure, with substantially less loss under alkaline, neutral, thermal and oxidative stress. That finding has a direct procurement consequence: light-protective packaging and a storage condition that keeps the material away from moisture and direct light are specification-relevant requests, not generic boilerplate.
A specification that names only "oclacitinib" is ambiguous at three separate points: which salt, which basis, and which grade. Naming the salt form and the CAS number together resolves all three at the point where it costs least to resolve them — in the enquiry, before a quotation is issued.
The same discipline applies to related substances. The impurity profile of the maleate salt includes the maleic acid counter-ion and its own related substances alongside the oclacitinib-derived impurities. A related-substances method written for the free base will not describe the salt completely, and a specification copied from a free-base dossier will leave a gap that neither party notices until an analytical review.
Oclacitinib maleate is released against an in-house specification rather than a pharmacopoeia monograph, and there is no compendial monograph for the material to be released against. The specification document the manufacturer issues is therefore the primary quality reference, and it should be requested and read before a quotation is compared.
An in-house specification is not a weaker document than a monograph; it is a different kind of document. A monograph is written by a pharmacopoeia and applies to every supplier of the material. An in-house specification is written by the manufacturer, applies to that manufacturer's process, and is the document a buyer has to assess on its own merits. That assessment is the subject of this section.
A complete specification for oclacitinib maleate addresses identity, assay, impurities, residual solvents, elemental impurities and physical form. The table below sets out what each parameter establishes and what evidence a buyer should expect alongside it.
| Parameter | What it establishes | Evidence to request |
|---|---|---|
| Identity | That the material is oclacitinib maleate and not the free base or another salt | IR spectrum, and a confirmatory test against a reference standard |
| Assay | The content of oclacitinib maleate, and the basis on which the figure is expressed | HPLC method with the basis stated in the same line |
| Related substances | The profile of oclacitinib-derived impurities, individually and in total | HPLC method with the limit for each named impurity |
| Maleic acid content | The counter-ion content, which confirms the salt stoichiometry | Titrimetric or chromatographic method |
| Residual solvents | Solvent classes present and the limits applied | Statement against the ICH Q3C framework |
| Elemental impurities | The elements assessed and the exposure basis applied | Assessment against the ICH Q3D framework |
| Loss on drying / water content | The moisture state of the batch, which affects the assay basis | Method and limit |
| Particle size | The physical form the downstream process has to handle | Method, typically laser diffraction, with a distribution |
| Appearance | Physical form and colour of the supplied powder | Visual descriptor |
| Identification of the salt | Confirmation that the counter-ion present is maleate | IR, or a specific test for maleate |
Residual solvents are classified and limited under the ICH Q3C framework, which groups solvents into classes by their toxicological potential and sets concentration limits for each. A specification that states only that the material complies with ICH Q3C has not told the buyer which solvents the process uses.
Elemental impurities are handled differently again. ICH Q3D is a risk-assessment framework, not a single pass-or-fail figure. It does not define one heavy-metals limit that applies to all materials; acceptable levels are derived per element from the route of administration and the maximum daily dose. A specification that states a single "heavy metals" figure does not, on its own, demonstrate conformity with the framework, because it does not show which elements were assessed or against which exposure basis the figure was set.
For a veterinary API destined for an oral dosage form, the assessment is available and the supplier should be able to produce it. Requesting it is not an unusual ask.
In-house specification status shifts the analytical burden. Where a monograph exists, a buyer can test against a published method and compare results across suppliers. Where none exists, the manufacturer's method becomes the reference, and the buyer's own method validation has to establish that the two are equivalent.
That has two practical consequences. First, request the analytical methods, not just the limits — a limit without its method cannot be reproduced. Second, ask whether a method transfer package is available, because a finished-product manufacturer filing a dossier will need one.
Every batch of oclacitinib maleate is accompanied by a batch-specific certificate of analysis, and the wider document set is issued for the material and the manufacturing site as a whole. The two categories answer different questions and a qualification file needs both.
A batch certificate proves that the drums that arrived were released against the specification. It says nothing about the quality system behind them. A site-level certificate proves that the site operates to a quality system; it says nothing about the individual batch. A buyer holding only one of the two has an incomplete file.
| Document | What it establishes | Issued by |
|---|---|---|
| Certificate of analysis (COA) | Batch number, test items, methods, results, specification limits and release authorisation for one batch | Manufacturer's quality control function |
| Specification document | The in-house specification the batch was released against | Manufacturer |
| Analytical methods | The procedures behind each test item, in enough detail to be reproduced or transferred | Manufacturer |
| Material safety data sheet (MSDS) | Handling, storage and transport classification | Manufacturer or supplier |
| GMP certificate | That the manufacturing site operates to Good Manufacturing Practice, and the scope covered | Held by the manufacturing site |
| Stability data summary | The storage conditions studied and the duration of supporting data | Manufacturer |
| TSE/BSE statement | A declaration addressing transmissible spongiform encephalopathy risk | Manufacturer |
| Residual solvent statement | The solvent classes present and the limits applied | Manufacturer |
Oclacitinib maleate as supplied from China holds no FDA registration number and no CEP number. That is a statement of fact about the material's registration position, not a deficiency in the material itself.
The consequence is that a buyer needing a US or European regulatory file cannot simply cite an existing one. The route is through the buyer's own dossier, supported by the manufacturer's open part — which is why the specification document, the methods and the stability summary carry more weight for this material than they would for a monographed one.
The stability summary should state the storage conditions studied, the duration of data behind the assigned re-test period and the analytical parameters followed. Those three items are what allow a buyer to verify that the assigned period is supported.
The published forced-degradation work on oclacitinib maleate found degradation under acidic conditions and under light exposure, with limited loss under alkaline, neutral, thermal and oxidative stress. A stability protocol that does not include a light-exposure arm is therefore incomplete for this material, and a storage condition that does not address light protection is worth questioning.
China is a production base for veterinary APIs, and oclacitinib maleate is available from Chinese manufacturers to an in-house specification. The sourcing question is not whether the material can be obtained but whether a given supplier's specification, analytical methods and documentation package are complete enough for the buyer's downstream file.
Because no pharmacopoeia monograph exists for the material, the buyer cannot fall back on a published standard to define what "correct" means. Everything the buyer will be held to downstream has to be written into the purchase specification and confirmed against the supplier's documents.
Four items determine whether the first reply is usable. Send all four together and the supplier can quote once; send them in sequence and the quotation is reissued each time.
| Item | What to state |
|---|---|
| Identity | "Oclacitinib maleate, CAS 1208319-27-0" — the salt form and the CAS number, not just the molecule name |
| Assay basis | Whether the assay figure is to be expressed on the salt or on the base, and whether it is on the anhydrous or the as-is basis |
| Specification | The parameter set above, or the buyer's own in-house specification with limits |
| Documentation | The document list required, and whether a method transfer package is needed |
A usable quotation names the specification it is quoted against. A quotation that gives a purity figure without a specification cannot be compared with another quotation, and comparing two such quotations is how buyers end up with materials that pass their own specification but fail their formulation.
Three verification points are worth building into the first round. Ask for the specification document by revision number, so that the specification quoted against is identifiable and does not change silently. Ask which analytical methods the results were generated on. And ask whether the certificate of analysis is issued per batch — a material-level certificate presented as a batch certificate is a common and avoidable confusion.
A specification written for the API should state the physical form, because the downstream process is designed around it. Particle-size distribution and bulk density are the two parameters that determine whether the material blends, flows and compresses the way the formulation was designed to.
Neither parameter appears in every in-house specification by default. Both are legitimate additions to a purchase specification, and asking for them at the enquiry stage costs less than discovering at the blending stage that the distribution does not match the process.
Oclacitinib maleate is quoted on request rather than against a published list, because the price of a given order is a function of the specification it is quoted against, the volume, the packaging and the documentation scope. Two quotations for the same nominal material are not comparable until those four variables are aligned.
The purpose of this section is to set out where the cost of an oclacitinib maleate order actually sits, so that a buyer can tell which differences between two quotations are real and which are artefacts of a different scope.
The specification is the largest single driver. An in-house specification with tighter individual impurity limits, a narrower particle-size distribution or an additional named impurity requires more process control, more analytical work and more rejected batches. Each of those is a cost, and each is invisible in a quotation that states only a purity figure.
A buyer who needs a tighter limit should expect the quotation to carry it. A buyer who does not need it should not pay for it — which is why the specification should be written before the enquiry rather than inherited from whichever supplier replied first.
Volume affects the per-unit cost through batch utilisation and through the fixed analytical cost spread across a batch. Packaging affects it through the container and the protective barrier required — for a material sensitive to light, the barrier is part of the specification rather than a logistics detail.
Documentation scope is the variable buyers most often leave unstated. A standard package and an expanded package that includes a method transfer, a stability summary and a regulatory support letter are different products with different costs. Stating the scope required in the enquiry is what makes them comparable.
| Item | Why it belongs in the quotation |
|---|---|
| Specification reference | Confirms which specification the figure is quoted against |
| Assay basis | Confirms whether the figure is on the salt or the base, anhydrous or as-is |
| Packaging | Confirms the container and the protective barrier |
| Documentation scope | Confirms which documents are included and which are extra |
| Price validity | Confirms the period the quotation holds for |
| Incoterm and origin port | Confirms where the price changes hands |
A quotation missing any of the six cannot be compared with another quotation, and a price comparison across two such quotations is a comparison of two different scopes.
Send the salt form, the assay basis, the dosage form, the destination market and the annual volume. We reply with the specification sheet, a specimen certificate of analysis and the current documentation package.